摘要
通过对2016年广州市南沙区的某化工企业雷达液位计两次因雷灾事故损坏情况的分析,找出了设备损坏原因,并提出相应的改进措施。
Through a chemical company in 2016 in Guangzhou city of Nansha District radar level meter two times due to damage of the lightning accident analysis, find out the reasons for the damage of equipment, and put forward the corresponding improvement measures. This paper analyzed the twice damage of radar level meter due to the lightning accident happened in a chemical company in Nansha of Guangzhou in 2016 and found out the reasons for the equipment damage. Furthermore, the corresponding improvement measures are put forward.
作者
钟博宏
王学孟
Zhong Bohong, Wang Xuemeng(Guangzhou meteorological public service center, Guangzhou Guangdong 51000)
出处
《气象研究与应用》
2017年第A02期77-78,共2页
Journal of Meteorological Research and Application
关键词
雷达液位计
雷击
屏蔽
防护措施
radar level meter
lightning stroke
shielding
protective measures