摘要 本文选取强降雨、一般降雨等几次天气过程,利用统计方法,对架设于南京的五个Parsivel降水粒子谱仪监测的资料和观测站雨量计雨量资料进行对比分析,结果得到:雨滴谱仪的雨量数据在降雨过程中与雨量计相差较小。雨强在10~20mm·h^(-1)之间时,雨滴谱仪的雨量与雨量计相差最大;雨强为0~1mm·h^(-1)和大于20mm·h^(-1)(短时强降雨)、或直径大于2mm时,雨滴谱仪雨量总体上大于雨量计;雨强为1~20mm、或直径小于2mm时雨滴谱仪雨量总体上小于雨量计。 This article selects some weather processes including heavy rainfall and general rainfall, using statistical method to contrast Parsivel precipitation particle spectrometer data and pluviometer data from five stations in Nanjing. The results show that the particle spectrometer data are close to the pluviometer data in rainfall processes. When the rain intensity is between 10-20 mm·h^-1, the particle spectrometer data have the largest difference from the pluviometer data. However, the particle spectrometer data are bigger than the pluviometer data as a whole when the rain intensity is either larger than 20 mm·h^-1 or between 0 and 1 mm·h^-1 , or when the rainfall particle diameter is bigger than 2 mm. The result is opposite when the rain intensity is between 1 and 20mm·h^-1, or when the particle diameter is smaller than 2 mm.
作者 李力 姜有山 蔡凝昊 夏敏洁 LI Li1, JIANG Youshan1, CAI Ninghao2 ,XIA Minjie1(1 Nanjing Meteorological Bureau, Nanjing 210009 ;2 Jiangsu Meteorological Observatory, Nanjing 21000)
出处 《气象》 CSCD 北大核心 2018年第3期434-441,共8页 Meteorological Monthly
基金 华东区域气象科技协同创新基金合作项目(QYHZ201604) 国家自然科学基金项目(41575010) 江苏省自然科学基金青年基金项目(BK20171094) 江苏省自然科学基金项目(BK20161603) 江苏省气象局预报员专项(JSYBY201409)共同资助
关键词 Parsivel降水粒子谱仪资料 雨量计雨量 对比分析 Parsivel precipitation particle spectrometer data, pluviometer data, contrastive analysis
  • 相关文献

参考文献13

二级参考文献145

共引文献256

同被引文献194

引证文献16

二级引证文献80

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部