期刊文献+

Clinical outcome of combined conjunctival autograft transplantation and amniotic membrane transplantation in pterygium surgery 被引量:12

Clinical outcome of combined conjunctival autograft transplantation and amniotic membrane transplantation in pterygium surgery
下载PDF
导出
摘要 AIM: To compare long-term outcome of primary and recurrent pterygium surgery with three different techniques: combined conjunctival autograft and overlay amniotic membrane transplantation (CAT with AMT), conjunctival autograft transplantation (CAT) alone and amniotic membrane transplantation (AMT) alone. METHODS: In this retrospective study, 142 eyes of 142 pterygium patients (104 primary, 38 recurrent)who underwent CAT (group A), AMT (group B) or CAT with AMT (group C) respectively following surgical excision were reviewed and compared based on the recurrences and post-operative complications. RESULTS: The number of recurrence post-surgery were 17 (9 from primary, 8 from recurrent; the same description below), 18 (10, 8) and 2 (1, 1) in groups A, B, and C respectively; dry eyes were 22 (16, 6), 27 (18, 9) and 7 (3, 4); conjunctival inflammations were 30 (17, 13), 27 (16, 11) and 11 (6, 5). Patients in group C (either pdmary or recurrent or both) mainly showed significantly better results than those in group A or B (P〈0.05) regarding above-mentioned clinical effects. CONCLUSION: Combined CAT and overly AMT have significantly lower rates of recurrence and postoperative complications for primary and recurrent pterygium surgery than CAT or AMT alone. AIM: To compare long-term outcome of primary and recurrent pterygium surgery with three different techniques: combined conjunctival autograft and overlay amniotic membrane transplantation (CAT with AMT), conjunctival autograft transplantation (CAT) alone and amniotic membrane transplantation (AMT) alone. METHODS: In this retrospective study, 142 eyes of 142 pterygium patients (104 primary, 38 recurrent)who underwent CAT (group A), AMT (group B) or CAT with AMT (group C) respectively following surgical excision were reviewed and compared based on the recurrences and post-operative complications. RESULTS: The number of recurrence post-surgery were 17 (9 from primary, 8 from recurrent; the same description below), 18 (10, 8) and 2 (1, 1) in groups A, B, and C respectively; dry eyes were 22 (16, 6), 27 (18, 9) and 7 (3, 4); conjunctival inflammations were 30 (17, 13), 27 (16, 11) and 11 (6, 5). Patients in group C (either pdmary or recurrent or both) mainly showed significantly better results than those in group A or B (P〈0.05) regarding above-mentioned clinical effects. CONCLUSION: Combined CAT and overly AMT have significantly lower rates of recurrence and postoperative complications for primary and recurrent pterygium surgery than CAT or AMT alone.
出处 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第3期395-400,共6页 国际眼科杂志(英文版)
基金 Supported by Natural Science Foundation of Jiangsu Province(No.BK20141346) Nanjing Science and Technology Development Plan(No.201402001)
关键词 PTERYGIUM amniotic membrane transplantation conjunctival autograft transplantation SURGERY pterygium amniotic membrane transplantation conjunctival autograft transplantation surgery
  • 相关文献

参考文献1

二级参考文献10

  • 1van Acker, E,de Potter, P.Implant orbitaire en poly-ethylene poreux (Medpor)[].J Fr Ophthalmol.2001
  • 2Solomon, A,Espana, E.M,Tseng, S.C.Amniotic membrane transplantation for reconstruction of the con-junctival fornices[].Ophthalmology.2003
  • 3Shields, C.L,Shields, J.A,de Potter, P,Singh, A.D.Lack of complications of the hydroxyapatite orbital im-plant in 250 consecutive cases[].Trans Am Ophthalmol Soc.1993
  • 4Sagoo, M.S,Olver, J.M.Autogenous temporalis fascia patch graft for porous polyethylene (Medpor) sphere or-bital implant exposure[].Br J Ophthalmol.2004
  • 5Oestreicher, J.H,Liu, E,Berkowitez, M.Complica-tions of hydroxyapatite orbital implants. A review of 100 consecutive cases and a comparison of Dexon mesh (polyglycolic acid) with scleral wrapping[].Ophthalmol-ogy.1997
  • 6Nakamura, T,Yoshitani, M,Rigby, H,Fullwood, N.J,Ito, W,Inatomi, T,Sotozono, C,Nakamura, T,Shimizu, Y,Kinoshita, S.Human sterilized freeze-dried amni-otic membrane: a useful substrate for ocular surface reconstruction[].Invest Ophthalmol Vis Sci.2004
  • 7McNab,A.Hydroxyapatite orbital implants. Experiencewith 100 cases[].Aust N Z J Ophthalmol.1995
  • 8Martin, P,Ghabrial, R.Repair of exposed hydroxya-patite orbital implant by a tarsoconjunctival pedicle flap[].Ophthalmology.1998
  • 9Lee, V,Subark, S.I,Hungerford, J.L,Davies, N.P,Logani, S.Exposure of primary orbital implants in pos-tenucleation retinoblastoma patients[].Ophthalmology.2000
  • 10Karesh, J.W,Dresner, S.C.High-density porous poly-ethylene (Medpor) as a successful anophthalmic socket implant[].Ophthalmology.1994