期刊文献+

梁(板)与柱(墙)节点区域不同强度等级混凝土施工质量控制 被引量:1

Construction Quality Control of Different Grade Concrete in the Joint Area of Beam(Floor) and Column(Wall)
下载PDF
导出
摘要 高层建筑的竖向构件和水平构件混凝土强度等级设计不同,施工过程中控制措施不到位,节点区域高等级混凝土浇筑高度不够,容易产生质量问题。文章分析了问题产生的原因,总结了施工控制措施,阐述了质量问题处理思路,供类似工程参考。 The concrete grade of vertical members and horizontal members in the high-rise buildings is different. If construction control method is not effective and the concreting height of the high grade concrete is low, engineer maybe emerge quality problem. The paper explains the reason of problem, summarizes the construction way and expounds the idea of solving the quality problem.
作者 李昌驭 LI Chang-yu(Nanjing Engineering Quality Verification Center of Construction and Installation, Nanjing Jiangsu 210017 Chin)
出处 《江苏建筑》 2018年第1期84-85,101,共3页 Jiangsu Construction
关键词 梁柱节点 不同等级混凝土 质量控制 质量问题处理 joint area of beam and column different grade concrete quality control disposing of qualityproblem