摘要 目的 对电感耦合等离子体质谱法(ICP-MS)测定妇必舒阴道泡腾片(FVET)中铜(Cu)、砷(As)、镉(Cd)、汞(Hg)、铅(Pb)含量的不确定度进行评价。方法 用ICP-MS法测定妇必舒阴道泡腾片中Cu、As、Cd、Hg、Pb的含量,建立数学模型,分析不确定度的来源,对灵敏系数和标准不确定度进行评定,计算合成扩展不确定度。结果 用ICP-MS法测定Cu、As、Cd、Hg、Pb的扩展不确定度分别为510、80、10、7、74μg·kg^(-1)。结论 所用方法适用于评定FVET中重金属的不确定度,可为中成药类重金属及有害元素含量的不确定度评定提供参考。 OBJECTIVE To establish a uncertainty analysis method for the determination of Cu, As, Cd, Hg, Pb in Fubishu vaginal effervescent tablets (FVET) by ICP - MS. METHODS The contents of Cu, As, Cd, Hg,Pb in FVET were detected by ICP - MS. The mathematical model was established,and the sources of uncertainty were analyzed,the sensitivity coefficient and the standard uncertainty were evaluated,and the expanded uncertainty was calculated. RESULTS The expanded uncertainties of Cu,As, Cd, Hg, Pb were 510, 80,10,7,74 μg·kg^(-1). CONCLUSION This method is applicable for the uncertainty evaluation of heavy metal determination in FVET. The more reliable result can be obtained when the measure was optimized by analyzing all standard uncertainty. It provides an important reference for the uncertainty evaluation of heavy metal determination in traditional Chinese medicine.
作者 郑明 胡卫南 程闯 柴鑫莉 ZHENG Ming, HU Weinan,CHEN Chuang,CHAI Xinli(Quzhou Institute for Food and Drug Control, Quzhou, Zhejiang,324000 P.R. Chin)
出处 《华西药学杂志》 CAS CSCD 2018年第2期202-206,共5页 West China Journal of Pharmaceutical Sciences
基金 浙江省衢州市重点实验室项目(衢市科发高[2015]8号)
关键词 妇必舒阴道泡腾片 不确定度 重金属有害元素 电感耦合等离子体质谱法 Fubishu vaginal effervescent tablets Uncertainty Heavy metal ICP - MS
  • 相关文献

参考文献2

二级参考文献11

  • 1张慧敏,陈登云,荆淼,刘小立,朴建华,王小如.应用ICP-MS的ORS技术进行人体铁稳定同位素代谢示踪研究的初探[J].卫生研究,2005,34(5):603-606. 被引量:3
  • 2中国药典[S].北京:中国医药科技出版社,2010:1182-1225.
  • 3Ch.P(2010)Vol I (中国药典 2010 年版.一部)[S]. 2010:115.
  • 4LI S A,SHI C Y, LIU F,et al. Evaluation and Expression ofUncertainty in Measurement(测量不确定度评定与表不.JJF1059-1999) [S]. Bureau of Quality and TechnologySupervision of the People’s Republic of China, 1999.
  • 5LIU D, CHEN C, WANG Q, et al. The evaluation of theuncertainty of quantitative determination of plumbum in soilby inductively coupled plasma mass spectrometry [J].环境科学导刊,2010, 29(6): 95-98.
  • 6ALLIBONE J, FATEMIAN E, WALKER P J. Determinationof mercury in potable water by ICP-MS using gold as astabilisingagent [J]. J Anal Atom Spectrom, 1999(14):235-239.
  • 7国家质量技术监督局.测量不确定度评定与表示[s].JJF1059-1999.1997:7-12.
  • 8国家质量技术监督局.常用玻璃量器检定规程[s].JJGl96-90.1990:10-12.
  • 9韦新红,魏雅娟,陈永欣,刘顺琼,阮贵武.电感耦合等离子体质谱(ICP-MS)法测定高纯氧化铟中铜含量的不确定度评定[J].中国无机分析化学,2011,1(2):50-53. 被引量:11
  • 10吴恙,陈泳鹏,林逸鹏,李振勇,张睿佳,刘洪涛,马安德.ICP-MS法测定矿泉水中铜、锰含量不确定度的研究[J].广东微量元素科学,2012,19(12):17-23. 被引量:1