摘要 超声波辐照有可能造成心肌细胞膜通透性和离子转运通道功能发生改变,从而影响心肌细胞膜除极和复极过程以及细胞内肌力相关离子浓度分布。超声波的上述生物学效应将影响心肌细胞内肌原纤维收缩功能并导致不同的肌力改变。近年来,相关基础实验和临床研究结果部分证实了超声波的正性肌力生物学效应。本文就该领域的基础与临床研究现状与进展做一述评,旨在为建立全新的无创物理学心力衰竭治疗方法提供进一步基础和临床研究的依据。 Key Laboratory of Ultrasound in Cardiac Electrophysiology and Bio-mechanics Ultrasonic irradiation might increase the membrane permeability of myocardial cell and change the function of trans-membrane ion transport channel, and would lead to an obvious change of depolarization and repolarization of membrane and inner concentration distribution of ions related force of myocardial cells finally. The existed biological effect of ultrasound irradiation might impact on the contractility of myofibrils within myocardial cells during systole and finally induce a change of myocardial contraction force in different ways regionally and globally. In recent years, the related experimental and clinical research results partly confirmed that the above biological effect of ultrasonic irradiation induced positive myocardial inotropic action of ultrasound. This commentary systematically reviews the existing research achievements in the field to provide the basis and clinical research fundament for establishing a new non-invasive physical treatment of heart failure further.
作者 尹立雪 YIN Lixue(Sichuan Key Laboratory, of Ultrasonic Cardiac Electrophysiology and Biomechanics, Sichuan Academy of Medical Sciences Sichuan Provincial People 's Hospital, Chengdu 610072, Chin)
出处 《西部医学》 2018年第4期469-473,共5页 Medical Journal of West China
基金 国家自然科学基金(81671852)
关键词 超声波 辐照 心力衰竭 正性肌力 Ultrasound Irradiation Heart failure Positive inotropic action
  • 相关文献

参考文献4

二级参考文献33

  • 1杨照康,臧益民,牛国保,朱妙章,王跃民.蟾蜍离体腓肠肌收缩过程中的阻抗变化及其意义[J].第四军医大学学报,1994,15(1):56-59. 被引量:1
  • 2赵婷,魏盛,方华强,王显花,郑铭,程和平.钙火花研究进展与瞻望[J].生物物理学报,2007,23(4):265-280. 被引量:10
  • 3Abdelmoneim SS,Bernier M, Scott CG, et al. Safety of contrast agent use during stress echocardiography: a 4-year experience from a single-center cohort study of 26,774 patients. JACC Cardiovasc Imaging,2009,2: 1048-1056.
  • 4Main ML, Ryan AC, Davis TE, et al. Acute mortality in hospitalized patients under-going echocardiography with and without an ultrasound contrast agent (multicenter registry results in 4,300,966 consecutive patients). Am J Cardiol, 2008, 102 : 1742-1746.
  • 5Dolan MS, Gala SS, Dodla S, et al. Safety and efficacy of commercially available ultrasound contrast agents forrest and stress echocardiography: a multicenter experience. J Am Coll Cardiol, 2009,53:32-38.
  • 6Aggeli C, Giannopoulos G, Roussakis G, et al. Safety of myocardial flash- contrast eehoeardiography in combination with dobutamine stress testing for the detection of ischaemia in 5,250 studies. Heart, 2008,94 :1571-1577.
  • 7Abdelmoneim SS, Bernier M, Scott CG, et al. Safety of contrast agent use during stress echocardiography in patients with elevated right ventricular systolic pressure:a cohort study. Circ Cardiovasc Imaging, 2010,3 : 240-248.
  • 8Miller DL, Quddus J. Diagnostic ultrasound activation of contrast agent gas bodies induces capillary rupture in mice. Med Sci, 2000,97: 10179-10184.
  • 9Miller DL,Li P,Gordon D, et al. Histological characterization of micro-lesions induced by myocardial contrast echocardiography. Echocardiography, 2005,22: 25-34.
  • 10Zen K, Okigaki M, Hosokawa Y, et al. Myocardium-targeted delivery of endothelial progenitor cells by ultrasound-mediated microbubble destruction improves cardiac function via an angiogenic response. J Mol Cell Cardiol, 2006,40 : 799-809.

共引文献10

同被引文献10

引证文献2

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部