摘要 为研究大直径复合绝缘子转轮法的试验方法和试验现象,设计并实现了一套适用于大直径试品的转轮法试验装置。进行了大直径复合绝缘子转轮法试验参数的探讨。对大、中、小3种直径的复合绝缘子试品分别进行了以去离子水、NaCl体积质量为0.4和0.7 kg/m^3的溶液为试验条件的长达168 h的转轮法试验。结果表明,在不同NaCl体积质量下,最大泄漏电流峰值均与试品平均直径近似呈线性关系。对于不同直径的试品,最大泄漏电流峰值与NaCl体积质量呈线性关系。标准试验条件下大直径试品的最大泄漏电流峰值可达144.2 mA。由试验结果可知,现有标准中规定的试验参数不适用于大直径的绝缘子试品,一些试验参数如NaCl体积质量需要进行调整,并给出了具体的推荐调整方案。 In order to study the test method and phenomena of tracking wheel test for composite insulator with large diameter,we designed and constructed a tracking wheel test device suitable for large-diameter specimens. Firstly, test parameters of tracking wheel test for composite insulator with large diameter were discussed. Then, three specimens, one with large diameter, one with medium diameter, and the other one with small diameter, were tested under the NaCl content of 0.0, 0.4 and 0.7 kg/m^3, respectively. Each test lasted for a week. The results show that, under different NaCl contents, the maximum peak value of leakage current is approximately linear to average diameter of the specimen. For specimens with different diameters, the maximum peak value of leakage current is linear to the NaCl content. Under the test conditions specified in the standard, the maximum peak value of leakage current reaches 144.2 mA. According to the test results, the test parameters in the current standards are not suitable for specimens with relatively larger diameters and some of them need to be adjusted, such as the NaCl content.Finally, a detailed adjustment method was proposed.
作者 梁曦东 李少华 高岩峰 罗兵 张福增 廖一帆 LIANG Xidong1, LI Shaohua1, GAO Yanfeng2, LUO Bing3, ZHANG Fuzeng3, LIAO Yifan3(1. State Key Laboratory of Control and Simulation of Power System and Generation Equipments, Department of Electrical Engineering, Tsinghua University, Beijing 100084, China; 2. Electric Power Research Institute of State Grid Jibei Electric Power Company, Beijing 100045, China; 3. Electrical Power Research Institute, China Southern Power Grid, Guangzhou 510080, Chin)
出处 《高电压技术》 EI CAS CSCD 北大核心 2018年第3期673-679,共7页 High Voltage Engineering
基金 特高压工程技术(昆明、广州)国家工程实验室开放基金(NEL201501)~~
关键词 复合绝缘子 转轮法试验 大直径 漏电起痕 电蚀损 泄漏电流 composite insulator tracking wheel test large diameter tracking erosion leakage current
  • 相关文献

参考文献12

二级参考文献193

共引文献330

同被引文献40

引证文献4

二级引证文献49

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部