期刊文献+

基于水泵转速控制的流量装置供水系统研究 被引量:2

Study on the Flow Facility’s Water Supply System Based on the Turn Speed Control of the Pump
下载PDF
导出
摘要 针对水流量标准装置分析了流量稳定性影响因素,提出了基于水泵转速控制的供水系统,研究了供水系统的控制策略,进行了多种工况的实验测试,在多家企/事业单位的水流量装置上进行了应用。实验测试和实际应用数据表明。水泵转速控制供水的流量稳定性与水塔供水的稳定性接近。在无水塔、无稳压容器的情况下,水泵转速控制供水的流量稳定性可达到优于0.1%的水平。为流量装置设计提供了一种新的,具有低成本、高稳定性、宽流量范围、节能等优点的供水方式。 The factors impacting the flow stability are analyzed for the water flow standard facility. A water supply system based on turn speed control of the pump is put forward. The control strategy of the water supply system is investigated. Experimental tests are carried out in many different working conditions. The water supply system is applied in many enterprises' water flow facilities. It is shown that, by the experimental test and practical application, the flow stability of the water supply system based on turn speed control of the pump is near that of the water tower. As there are not the water power and the pressure dumping tank, the flow stability of the water supply system based on turn speed control of the pump can reach a level better than 0.1%. A new way of water supply with merits of low cost, high stability, wide flow rate range, and saving energy is offered for flow facility design.
作者 刘大伟 孙立军 曹宇虹 陈卓 张涛 LIU Da-wei;SUN Li-jun;CAO Yu-hong;CHEN Zhuo;ZHANG Tao(School of Electrical Engineering & Automation, Tianjin University, Tianjin 300072, Chin)
出处 《控制工程》 CSCD 北大核心 2018年第4期570-576,共7页 Control Engineering of China
关键词 流量装置 流量稳定性 供水系统 水泵 转速控制 Flow facility flow stability water supply system pump turn speed control
  • 相关文献

参考文献2

二级参考文献17

  • 1袁璞,左信,郑海涛.状态反馈预估控制[J].自动化学报,1993,19(5):569-577. 被引量:56
  • 2郭建林.水流量标准装置性能评价与提高节流装置的标定精度[J].动力工程,1990,10(3):39-44. 被引量:4
  • 3朱德祥,张延柱,朱福茂.流量仪表的原理与应用[M].上海:华东化工学院出版社.1992.
  • 4国家质量技术监督局.JJG1642000.中华人民共和国国家计量检定规程,液体流量标准装置[S],2001.
  • 5陈福庆,郭延,郭殿杰.水流量仪表检定装置的自动控制[Z].99工业仪表与自动化学术会议,1999:217-223.
  • 6陈寿平.水流量标准装置测试稳定改进与研究[D]:上海.上海理工大学动力工程学院,2005.
  • 7苏彦勋, 范怗. 流量装置的换向器和系统稳定性问题的研究[A]. 流量测量技术与仪表学术交流会论文集[C], 1996, 28~39.
  • 8Bristol E H. On a new measure of interactions for multivariable process control [ J ]. IEEE Transactions on Automatic Control, 1966, 11(2): 133-134.
  • 9He Mao-Jun, Cai Wen-jian, Ni Wei, et al. RNGA based control system configuration for multivariable processes [ J ]. Journal of Process Control, 2009, 19(7): 1036-1042.
  • 10Witcher M, McAvoy T J. Interacting control Systems: Steady state and dynamic measurement of interaction [ J ]. ISA Trans, !977, 16 (3) :83-90.