摘要
采用Sun FirePrep Silica正相色谱柱,选用V(二氯甲烷)∶V(正己烷)=60∶40为流动相,在检测波长为417 nm、流速为1 m L/min、柱温为25℃的条件下,建立了对meso-苯基-4-吡啶基取代卟啉混合物进行定量分析的正相高效液相色谱方法。在该定量分析方法中,6种卟啉的标准曲线线性相关系数均大于0.999 3,相对标准偏差均小于1.28%,加标回收率在96.4%~103.9%之间。实验结果表明,该定量分析方法可用于meso-苯基-4-吡啶基取代卟啉混合物的同时测定。
A method for the quantitative analysis of meso-phenyl-4-pyridyl substituted porphyrins was established by normal phase high performance liquid chromatography( NP-HPLC).NP-HPLC was carried out on a Sun FirePrep Silica normal column,using V( dichloromethane) ∶ V( n-hexane) = 60 ∶40 as the mobile phase and the detection was performed by PAD detector at 417 nm,of which flow rate was 1. 0 m L/min and the column temperature was 25 ℃.In the quantitative analysis method,the linear correlation coefficients of all the six porphyrins were more than 0. 999 3,the relative standard deviations were less than 1. 28%,and the recoveries were between 96. 4% and 103. 9%.This method can be used for the simultaneous determination of meso-phenyl-4-pyridyl substituted porphyrins.
作者
赵文伯
王娇娇
崔艳艳
秦会安
ZHAO Wen-bo;WANG Jiao-jiao;CUI Yan-yan;QIN Hui-an(College of Chemistry and Chemical Engineering, Zhengzhou Normal University, Zhengzhou 450044, Chin)
出处
《化学试剂》
CAS
北大核心
2018年第4期345-347,392,共4页
Chemical Reagents
基金
河南省基础与前沿技术研究资助项目(152300-410001)
郑州市普通科技攻关项目(153PKJGG147)
关键词
meso-苯基-4-吡啶基取代卟啉
正相高效液相色谱
定量分析
meso-phenyl-4-pyridyl substituted porphyrin
normal phase high performance liquid chromatography
quantitative analysis