摘要 某抽水蓄能机组在整组启动试运行时导轴承摆度偏大,分析发现转子质量失衡引起的不平衡力是该机组机械振动的主要激振源之一。将时域-频谱与不卸试重块的影响系数相结合的分析方法应用于该机组转子动平衡试验中,结果表明该方法具有判断失重角相位精度高、不用卸试重块及启机次数少等优点,为抽水蓄能机组转子动平衡研究提供了新思路。 The guide bearing swing of one pumped storage power unit was larger during the unit complete start-up test,and it found that the unbalance force caused by mass imbalance of rotor was one of the main mechanical vibration sources.The combination analysis method of time domain spectrum and the influencing coefficient without unloading heavy was applied in dynamic balance test.The results show that this method had advantages of high precision for judging the weightlessness angle phase,not unloading heavy and less starting,which provided a new idea for dynamic balance study of pumped storage power unit rotor.
作者 冯雁敏 王千 荆凯 FENG Yan-min;WANG Qian;JING Kai(Electric Power Research Institute of State Grid Liaoning Electric Power Co. ,Ltd. , Shenyang 110006 ,China)
出处 《水电能源科学》 北大核心 2018年第4期165-169,共5页 Water Resources and Power
关键词 抽水蓄能机组 动平衡 时域 频谱 影响系数法 pumped storage power unit dynamic balance time domain spectrum influencing coefficient method
  • 相关文献

参考文献6

二级参考文献34

  • 1唐一科,顾乾坤.现场转子双面动平衡的单双试重组合测试法[J].重庆大学学报(自然科学版),1993,16(5):92-96. 被引量:3
  • 2姚大坤,邹经湘,胡建文.水轮发电机转子动平衡的时-频方法[J].水力发电,2005,31(8):56-58. 被引量:8
  • 3谢志江 唐一科 等.VTC型增压器振动故障诊断及治理措施的研究[J].重庆大学学报,1999,22(4):159-162.
  • 4GB/T15468-2006水轮机基本技术条件[S].北京:中国标准出版社,2006.
  • 5李启章.对大型机组振动、裂纹问题的探讨[A]..大中型混流式水轮机运行稳定性-全国水轮机标准化技术委员会论文集专集二[C].,2004.40-42.
  • 6水电六局 四局.水轮发电机的安装[M].北京:水利电力出版社,1979..
  • 7姚大坤.大龙潭水电站1号机组振动故障处理[A]..电力系统安全[M].北京:中国经济出版社,2004.898-901.
  • 8张济生.刚性转子现场平衡的实用方法[J].试验机与材料试验,1987,3:12-19.
  • 9刘晓亭,冯辅周.水电机组运行设备监测诊断技术及应用[M].北京:中国水利水电出版社,2010.
  • 10万莉莉.基于WinCE平台的ARM转子动平衡技术研究[D].上海:上海师范大学,硕士论文,40-48.

共引文献33

同被引文献6

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部