期刊文献+

Monitoring magnesium degradation using microdialysis and fabric-based biosensors 被引量:1

Monitoring magnesium degradation using microdialysis and fabric-based biosensors
原文传递
导出
摘要 This paper describes the development of a monitoring system capable of detecting the concentration of magnesium ions(Mg^(2+)) released during the degradation of magnesium implants. The system consists of a microdialysis probe that samples fluid adjacent to the implant and a catalytic biosensor specific to Mg^(2+)ions. The biosensor was fabricated on a cotton fabric platform, in which a mixture of glycerol kinase and glycerol-3-phosphate oxidase enzymes was immobilized on the fabric device via a simple matrix entrapment technique of the cotton fibers. Pure magnesium was used as the implant material. Subsequently, the concentration of ions released from the degradation of the magnesium specimen in Ringer's solution was evaluated using cyclic voltammetry technique. The device demonstrated a pseudo-linear response from 0.005 to 0.1 mmol L^(-1) with a slope of 67.48 μA mmol^(-1) L. Detectable interfering species were lesser than 1%indicating a high selectivity of the fabric device. Furthermore,the device requires only 3 μL of fluid sample to complete the measurement compared to spectroscopic method(±50 μL),hence providing a higher temporal resolution and reduced sampling time. The system could potentially provide a real time assessment of the degradation behavior, a new studied aspect in biodegradable metals research. This paper describes the development of a monitoring system capable of detecting the concentration of magnesium ions(Mg2+) released during the degradation of magnesium implants. The system consists of a microdialysis probe that samples fluid adjacent to the implant and a catalytic biosensor specific to Mg2+ions. The biosensor was fabricated on a cotton fabric platform, in which a mixture of glycerol kinase and glycerol-3-phosphate oxidase enzymes was immobilized on the fabric device via a simple matrix entrapment technique of the cotton fibers. Pure magnesium was used as the implant material. Subsequently, the concentration of ions released from the degradation of the magnesium specimen in Ringer’s solution was evaluated using cyclic voltammetry technique. The device demonstrated a pseudo-linear response from 0.005 to 0.1 mmol L-1 with a slope of 67.48 μA mmol-1 L. Detectable interfering species were lesser than 1%indicating a high selectivity of the fabric device. Furthermore,the device requires only 3 μL of fluid sample to complete the measurement compared to spectroscopic method(±50 μL),hence providing a higher temporal resolution and reduced sampling time. The system could potentially provide a real time assessment of the degradation behavior, a new studied aspect in biodegradable metals research.
出处 《Science China Materials》 SCIE EI CSCD 2018年第4期643-651,共9页 中国科学(材料科学(英文版)
基金 supported by the Malaysian Ministry of Education the Natural Sciences and Engineering Research Council of Canada (NSERC)
关键词 biodegradable metal BIOSENSOR fabric device MAGNESIUM MICRODIALYSIS biodegradable metal biosensor fabric device magnesium microdialysis
  • 相关文献

参考文献1

二级参考文献13

  • 1Staiger M P, Pietak A M, Huadmai J, et al. Magnesium and its alloys as orthopedic biomaterials: A review. Biomaterials, 2006, 27: 1728-1734.
  • 2Witte F, Kaese V, Haferkamp H, et al. In vivo corrosion of four magnesium alloys and the associated bone response. Biomaterials, 2005, 26:3557-3563.
  • 3Yamasaki Y, Yoshida Y, Okazaki M, et al. Synthesis of functionally graded MgCO3 apatite accelerating osteoblast adhesion. J Biomed Mater Res, 2002, 62:99-105.
  • 4Witte F, Fischer J, Nellesen J, et al. In vitro and in vivo corrosion measurements of magnesium alloys. Biomatefials, 2006, 27: 1013-1018.
  • 5Witte F. The history of biodegradable magnesium implants: A review. Acta Biomater, 2010, 6:1680-1692.
  • 6Fathi M H, Hanifi A. Evaluation and characterization of nanostructure hydroxyapatite powder prepared by simple sol-gel method. Mater Lett, 2007, 61:3978-3983.
  • 7Qu H B, Wei M. The effect of fluoride contents in fluoridated hydroxyapatite on osteoblast behaviour. Acta Biomater, 2006, 2: 113-119.
  • 8Song Y, Zhang S X, Li J N, et al. Electrodeposition of Ca-P coatings on biodegradable Mg alloy: In vitro biomineralization behavior. Acta Biomater, 2010, 6:1736-1742.
  • 9Lamolle S F, Monjo M, Rubert iV, et al. The effect of hydrofluoric acid treatment of titanium surface on nanostructural and chemical changes and the growth of MC3T3-E1 cells. Biomaterials, 2009, 30: 736-742.
  • 10Wen C L, Guan S K, Peng L, et al. Characterization and degradation behaviour of AZ31 alloy surface modified by bone-like hydroxyap- atite for implant applications. Appl Surf Sci, 2009, 255:6433-6438.

同被引文献7

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部