探究渐进多焦点自由曲面镜片非对称设计过程中,内偏移量对镜片光学性能的影响。推导人眼在观察物体时,双眼汇聚而内转的偏移量计算公式。仿真在同等参数条件下,为实现左右眼平衡设计及在视觉生理上的视像对称,渐进多焦点自由曲面镜片下加光区四种不同的内偏移量产生的光焦度和散光分布图。通过仿真结果得出,不同的内偏移量对镜片的光焦度和散光分布有一定的影响,特别是周边像散区的分布大小;渐进多焦点自由曲面镜片的内偏移量应根据屈光不正患者实际的验光参数计算得到。
To research the influence of different internal offset values for the optical properties of progressive addition freeform lenses on asymmetric design.Calculation formula of the internal offset value is deduced when the human eye observed the object.In order to achieve the left and right eye balance design and visual physiology of the video symmetry,the power and astigmatism distribution maps of the down addition viewing zone for progressive addition freeform lenses with four different offset values were simulated in the same parameters.According the simulation power and astigmatism maps of four lenses by FFV software based on Moire deflection.It is indicated that there is a certain impact for the lenses of the optical power and astigmatism distribution with the different internal offset values,especially the size of astigmatism distribution in the peripheral zone.The internal offset values of progressive addition freeform lenses should be calculated based on the actual optometry parameters of the patient with refractive error.
作者
项华中
武杰
付东翔
郑刚
王成
陈家璧
庄松林
XIANG Huazhong;WU Jie;FU Dongxiang;ZHENG Gang;WANG Cheng;CHEN Jiabi;ZHUANG Songlin(School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China;School of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China)
出处
《光学技术》
CAS
CSCD
北大核心
2018年第2期147-151,共5页
Optical Technique
基金
国家自然科学基金青年基金项目(61605114)
关键词
渐变焦镜片
内偏移
仿真
双眼汇聚
progressive addition lens
offset
converging
binoculus
simulation