摘要
微通道换热器具有集成度高、换热效率高及成本低等特点,本文归纳微通道换热器应用于热泵空调时制冷剂充注量、系统COP等性能参数,并与传统热泵空调进行对比,同时还就热泵空调应用微通道时空气侧的阻力与传热的影响因素进行了分析讨论。结果表明,将微通道换热器替代常规换热器,其换热系数及系统COP均有大幅度提升,且缩减了制冷剂充注量,因此将微通道换热器替代常规尺度换热器对于节能降耗意义十分重大。
Micro- channel heat exchanger has the characteristics of high integration, high heat transfer efficient and low cost and so on. Performance parameters such as refrigerant charge amount and system COP were summarized for heat pump air - conditioning with micro - channel heat exchanger and compared with traditional heat pump air - conditioning. Furthermore, the influence factor for air side resistance and heat transfer used micro - channel was also discussed. The results show that the heat transfer coefficient and system COP increase and refrigerant charge amount is reduced for traditional heat exchanger replaced by micro - channel heat exchanger. Therefore, the micro - channel heat exchanger has important significant for energy saving and cost - reducing.
作者
池帮杰
代苏苏
鲁进利
韩亚芳
马登辉
Chi Bangjie;Dai Susu;Lu Jinli;Han Yafang;Ma Denghui(School of Civil Engineering and Architecture, Anhui University of Technology, Ma' anshan 243032, Chin)
出处
《低温与超导》
CAS
北大核心
2018年第4期63-67,共5页
Cryogenics and Superconductivity
基金
国家自然科学基金项目(51306002)
安徽省自然科学基金项目(1508085QE95)
大学生创新创业训练计划项目(201710360046)资助
关键词
微通道换热器
热泵空调
制冷剂充注量
系统性能
Micro - channel heat exchanger, Heat pump air - conditioning, Refrigerant charge amount, System performance