摘要 制药废水是一种污染比较大且比较难处理的一种工业废水,废水中含有大量的抗生素、盐分等物质,治理工艺选择不当必然造成污水处理频繁瘫痪,从而影响企业的生产发展,严重时将造成环境污染事故。治理制药废水,必须弄清楚制药工艺的排水情况,从源头上将排水进行分质分流并进行适当的预处理,其中重点是将高浓度COD含量、高抑菌类的复杂有机物及高盐分的废水进行适当处理后使其具备生化的条件后再与其他低浓度的废水混合进行集中处理,这样才能使整个污水处理系统能稳定连续的运行。 Otics, salt and other substances. Improper selection of treatment process will inevitably lead to the frequent paralysis of sewage treatment system, thus affecting the production and development of enterprises, serious environmental pollution accidents will occur. In order to treat pharmaceutical wastewater, it is necessary to make clear the drainage situation of phan'naceutical process, separate the drainage from the source by quality and carry out proper pretreatment. The key point is to treat the wastev, ater with high concentration of cod, high bacteriostatic complex organic matter and high salinity properly, then mix it with other low concentration wastewatcr for centralized treatment, so that the whole sewage treatment system can run stably and continuously.
作者 令狐义波 Linghu Yibo(Guangdong STI Engineering Technology Co., Ltd., Dongguan 523808, Chin)
出处 《广东化工》 CAS 2018年第8期193-194,191,共3页 Guangdong Chemical Industry
关键词 制药废水 分类处理 高级氧化 pharmaceutical wastewater sorting process advanced oxidation
  • 相关文献

参考文献2

二级参考文献15

  • 1张艳芳,霍莹,张莹,张健,李品娟.采用氧化-生化法处理制药废水[J].工业水处理,2004,24(11):63-65. 被引量:9
  • 2李向东,冯启言.水解—好氧处理制药废水的试验研究[J].环境科学与技术,2006,29(1):82-83. 被引量:16
  • 3国家环境保护总局 水和废水监测分析方法编委会.水和废水监测分析方法(第4版)[M].北京:中国环境科学出版社,2002.210-213.
  • 4Neyens E. , Baeyens J. A review of classic Fenton' s per- oxidation as an advanced oxidation technique. Journal of Hazardous Materials, 2003, 98 ( 1-3 ) : 33-50.
  • 5Zimbron J. A. , Reardon K. F. Fenton' s oxidation of pen- tachlorophenol. Water Research, 2009, 43 ( 7 ): 1831-1840.
  • 6Badawy M. I., Ghaly M. Y., Gad-Allah T. A. Advanced oxidation processes for the removal of organophosphorus pesticides from wastewater, Desalination, 2006, 194 ( 1- 3) : 166-175.
  • 7Badawy M. I., Wahaab R. A., E1-Kalliny A. S. Fenton- biological treatment processes for the removal of some phar- maceuticals from industrial wastewater. Journal of Hazard- ous Materials, 2009, 167(1-3) : 567-574.
  • 8Sirtoria C. , Zapataa A. , Oiler I. , et al. Decontamination industrial pharmaceutical wastewater by combining solar photo-Fenton and biological treatment. Water Research, 2009, 43(3) : 661-668.
  • 9Papadopoulos A. E. , Fatta D. , Loizidou M. Develop- ment and optimization of dark Fenton oxidation for the treatment of textile wastewaters with high organic load. Journal of Hazardous Materials, 2007, 146 (3) : 558-563.
  • 10Wang S. B. A comparative study of Fenton and Fenton- like reaction kinetics in decolourisation of wastewater. Dyes and Pigments, 2008, 76(3) : 714-720.

共引文献54

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部