摘要
建立甲硫醇、二甲二硫醚、甲硫醚三种恶臭气体在工作场所空气中的检测方法:利用苏玛罐采样,冷阱预浓缩处理样品,气相色谱质谱联用法测定其浓度,检测限可达到0.05μg/m^3,加标回收率也可以控制在在86%-102.4%范围,样品测试的相对标准偏差<1.0%,反映出此方法准确度高、重复性好,同时操作便捷。
The establishment of methanethiol, dimethyl disulfide, methyl sulfide three kinds of foul gases in the workplace air detection methods: the use of Suma tank sampling, cold trap preconcentration samples, gas chromatography-mass spectrometry determination of its concentration, detection The limit can reach 0.05 mg/m3, the spike recovery rate can also be controlled in the range of 86 %-102.4 %, the relative standard deviation of the sample test is less than 1.0 %, reflecting the high accuracy and repeatability of the method and the convenient operation.
作者
杨万斌
李小兰
Yang Wanbin;Li Xiaolan(SoAo Analysis Laboratory, Shenzhen 518126, China)
出处
《广东化工》
CAS
2018年第7期234-235,共2页
Guangdong Chemical Industry