摘要 环境条件对光伏光热(PV/T)系统性能的影响十分显著。文章通过改变实验室内部的环境条件,对比分析了通风、密闭条件下,不同冷却水流量对PV/T系统的输出性能以及光伏组件温度的影响。实验结果表明:密闭条件下PV/T组件工作温度与周围环境温度的平均值比通风条件下高出约7℃;密闭条件下PV/T系统的输出功率、热效率比通风条件下分别增大约3.5%,13%。 The performance of the photovoltaic/thermal(PV/T)system could be significant varied with environmental conditions.This paper has comparatively analyzed the output performances of the PV/T system and temperature variations of the PV/T component under airtight and ventilation conditions,which are impacted by the mass flow rate of the cooling water via changing the laboratory indoor environmental factors.The results show that the average temperatures of the PV/T component and around environment would be higher of 7 ℃ in the airtight than ventilation.In addition,the output power of PV/T system has increased by 3.5% under airtight than ventilation.Similarly,the thermal efficiency of the PV/T system could be increased by 13%.
作者 庞玮 于洪文 张林睿 崔雅楠 张永哲 严辉 Pang Wei;Yu Hongwen;Zhang Linrui;Cui Yanan;Zhang Yongzhe;Yan Hui(College of Materials Science and Engineering, Beijing University of Technology, Beijing 100124, China;College of Materials Science and Engineering, Wuhan University of Technology, Wuhan 430070, China)
出处 《可再生能源》 CAS 北大核心 2018年第4期501-505,共5页 Renewable Energy Resources
基金 国家自然科学基金面上项目(61574009)
关键词 环境因素 温度变化 系统性能 environmental factors temperature variations system performances
  • 相关文献

参考文献6

二级参考文献64

  • 1刘莉敏,曹志峰,许洪华.50kW_p并网光伏示范电站系统设计及运行数据分析[J].太阳能学报,2006,27(2):146-151. 被引量:30
  • 2卢峰,张华,姚秀平,黄惠兰.太阳能热风发电关键技术综述[J].华东电力,2006,34(3):1-3. 被引量:7
  • 3卢峰,张华,姚秀平,黄惠兰.太阳能热风发电系统集热器热物理模型及分析[J].可再生能源,2007,25(2):7-9. 被引量:5
  • 4SCHLAICH J. The solar chimney:Electricity from the sun[M]. Maurer C, Geislingen, Germany, 1995.
  • 5BERNARDESMA D S, VALLE R M, CORTEZ M F B. Numerical analysis of natural laminar convection in a radial solar heater[J].Int J Therm Sci, 1999;38:42-50.
  • 6BACKSTROM T W VON, GANNON A J. The solar chimney air standard cycle [J].South African Institution of Mechanical Engineering R&D,2000,16:16- 24.
  • 7GANNON A J., BACKSTROM T W VON, Solar chim, ney cycle analysis with system loss and solar collector performance [J].J Sol. Energy Eng.,2000,122,133-137.
  • 8MEKHILEF, S SAIDUR,R KAMALISARVESTANI M. Effect of dust humidity and air velocity on efficiency of photovohaic cells [J]. Renewable and Sustainable En- ergy Reviews, 2012 (5) : 2920-2925.
  • 9G M TINA, ABATE R. Experimental verification of ther- mal behaviour of photovoltaic modules [A]. 2008 IEEE Mediterranean Electroteehnical Conference[C].Ajac- cio,France : IEEE, 2008.579-584.
  • 10ADEL A, HEGAZY. Effect of dust accumulatin on solar transmittance through glass covers of platetype collectors [J]. Renewable Energy, 2001 (22) :525-540.