期刊文献+

三元件失步保护透镜内角和灵敏角的校验方法

A calibration method for three-component out-of-step protection for the interior angle and sensitivity angle of the lens
下载PDF
导出
摘要 在介绍了三元件失步保护的原理和整定方法后,通过分析和比较各种保护校验方法的优缺点,总结了这些方法不一定能准确校验定值动作边界的原因,同时指出了这些校验方法都无法对透镜内角和灵敏角进行校验,最后提出了透镜内角和灵敏角的校验方法,并以典型值为例说明了该方法。 After introducing the principle and setting method of three-component out-of-step protection,the advantages and disadvantages of various calibration methods for protection are analyzed and compared,and the reason why these methods may not be able to accurately verify the boundary of definite action is summarized.Meanwhile,it is pointed out that these calibration methods can not verify the interior angle and the sensitivity angle of the lens.Finally,the calibration method for the interior angle and the sensitivity angle of the lens is put forward and described by taking the typical value as an example.
作者 霍震
出处 《电力科技与环保》 2018年第2期49-51,共3页 Electric Power Technology and Environmental Protection
关键词 失步保护 机端阻抗 阻抗直线 透镜内角 状态序列 out- of- step protection Impedance of the generator terminal Impedance straight line Interior An-gle of the lens state sequence
  • 相关文献

参考文献2

二级参考文献23

  • 1毕玉修,卞超.应用SF_6气体分解物进行电气设备故障诊断的探讨[J].江苏电机工程,2007,26(5):14-17. 被引量:32
  • 2陈振生.GIS高压电器SF_6气体密度、湿度及泄漏检测技术[J].电气技术,2007,8(4):16-20. 被引量:18
  • 3王茜,杨文娟.中国风电发展历程及相关建议[J].风能,2013(6):42-48. 被引量:8
  • 4DL/T393-2010输变电设备状态检修试验规程[s].2010.
  • 5GB/T8905-2010六氟化硫电气设备中气体管理和检测导则.
  • 6DL506-2007,六氟化硫气体绝缘设备中水分含量现场测量方法[s].
  • 7Junya Suehiro, Guangbin Zhou, Masanori Hara. Detection of partial discharge in SF6 gas using a carbon nanotube - based gas sensor [ J ]. Sensors and Actuators ,2005,105 (2) : 164 - 169.
  • 8甘肃省电力公司.2013年年度运行方式[R].兰州:甘肃省电力公司.2013.
  • 9国网甘肃省电力公司.2014年甘肃省电力公司十件大事[N].兰州:甘肃电力报,2015-01-20.
  • 10张谦,李琥,高松,等.风电对调峰影响的概率化分析及其合理利用模式研究[C].中国电机工程学会第十一届青年学术会议.北京:2010.

共引文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部