期刊文献+

氟化废水臭气处理工程实例 被引量:3

Example of a Fluoride Wastewater Odor Treatment Project
原文传递
导出
摘要 某氟化企业污水处理厂臭气处理工程,针对臭气成分复杂、浓度高的特点,以两级碱洗+生物滤池+植物液喷淋为主体工艺,合理配置附属设备,处理效果稳定,处理后的气体满足《恶臭污染物排放标准》(GB 14554—1993)的二级排放标准。 The odor treatment project of a fluoride enterprise sewage treatment plant is aimed at the complex and high concentration of odor. The main process uses two stages of alkali washing, biologi- cal filter, and plant extract spray. The ancillary equipment is rationally allocated, and the treatment effect is stable. The emissions could meet the second level criteria in Emission Standards for Odor Pollu- tants ( GB 14554 - 1993).
作者 王雄 郑泽鑫 WANG Xiong;ZHENG Ze-xin(Academy of Environmental Planning & Design Co. Ltd., Nanjing University, Nanjing 210093, China;Jiangsu Honest Environmental Protection Technology Co. Ltd., Nanjing 210046, China)
出处 《中国给水排水》 CAS CSCD 北大核心 2018年第8期106-109,共4页 China Water & Wastewater
关键词 氟化企业 污水处理 臭气 生物滤池 植物液 fluoride enterprise sewage treatment odor biological filter plant extract