期刊文献+

600MW机组投运低温省煤器热力系统经济性分析 被引量:1

THERMAL SYSTEM ECONOMIC STUDY ON ADDING LOW TEMPERATURE ECONOMIZER ON A 600 MW UNIT
下载PDF
导出
摘要 通过热耗率试验,确定了某600MW机组投运该联接方式低温省煤器后对该机组热力系统经济性的影响。汽轮机组在620MW、500MW、330MW试验负荷工况下,当低温省煤器投入运行之后,凝结水经低温省煤器吸热后温度分别升高了22.2℃、19.94℃、18.51℃;锅炉排烟温度分别降低14.6℃,16℃,22.8℃;汽轮机组热耗率分别降低了58.44kJ/(kW·h),43.09kJ/(kW.h),42.5kJ/(kW·h);供电煤耗分别降低2.33g/(kW·h),1.82g/(kW·h),1.87g/(kW·h);厂用电率均不同程度下降。实现了热力系统经济性提高的目标。 To determine the effect on the economy of the thermal system of a 600MW steam turbine after commissioning low temperature economizer,one heat rate test was done. Steam turbine at 620 MW,500MW,330MW test load conditions,When put into operation low temperature economizer,condensate water temperatures was increased by 22.2℃、19.94℃、18.51℃ ; Boi ler smoke temperature were lower 14.6%, 16%, 22.8%; Steam turbine heat rate were reduced 58.44kJ/(kW·h),43.09kJ/(kW·h),42.5kJ/(kW·h)at each test load conditions,the power supply coal consumption decreased by 2.33g/(kW·h), 1.82g/(kW·h), 1.87g/(kW·h) ;The electricity rate of the plant has decreased in different degrees, which realized the purpose of enhancing thermal system economic.
作者 刘源 付晓俊 LIU YUAN;FU XIAOJUN(Sichuan Electric Power Design&Consulting Co..Ltd)
出处 《区域供热》 2018年第2期119-123,共5页 District Heating
关键词 低温省煤器 热耗率试验 热力系统 经济性 Low temperature economizer Heat rate test Thermal system, Economic