期刊文献+

核电站应急给水系统对蒸汽喷射泵的性能要求分析 被引量:3

Performance Analysis of a Steam-driven Injector for Emergency Feedwater System of Nuclear Power Plant
下载PDF
导出
摘要 针对采用蒸汽喷射泵的核电站应急给水系统,提出了简化的应急给水需求分析方法。根据AP1000核电厂的主要参数,对停堆过程中一回路冷却要求进行分析,得到机组维持热备用温度和冷却过程对蒸汽喷射泵的性能要求。结果表明:在停堆的不同阶段要求蒸汽喷射泵能适应变工况运行,因此设计中可以采用不同的蒸汽喷射泵配置形式,通过调节汽水参数以满足性能要求。 A simplified analysis method was proposed for the demand of emergency feedwater by nuclear power plant using steam-driven injector.According to the parameters of AP1000 nulcear power plant,the cooling water demand in primary loop was analyzed during shutdown period,so as to obtain the requirement on performance of the steam-driven injector in the process of hot and cold standby.Results indicate that,the steam-driven injector is required to operate at various cases during shutdown period,so different configurations can be adopted in the design of steam-driven injectors,thus meeting the performance requirement of steam-driven injector through adjustment on relevant steam and water parameters.
作者 武心壮 WU Xinzhuang(Shanghai Nuclear Engineering Research and Design Institute Co. , Ltd. , Shanghai 200233, Chin)
出处 《动力工程学报》 CAS CSCD 北大核心 2018年第4期337-340,共4页 Journal of Chinese Society of Power Engineering
关键词 核电站 应急给水 衰变热 蒸汽喷射泵 喷射系数 nuclear power plant emergency feedwater decay heat steam-driven injector entrainment ratio
  • 相关文献

参考文献7

二级参考文献29

共引文献40

同被引文献15

引证文献3

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部