摘要 针对660 MW超临界机组投产以来,#4机组闭式水泵频繁发生泵断裂事件进行研究分析,并采取措施予以解决,供同类设备维护参考。 Since the 660 MW supercritical units were put into operation,the shaft fractures occurred frequently in the closed pump of the#4 unit.The failure was researched and analyzed.Measures were taken to solve it for reference of similar equipment maintenance.
作者 贺宏彦 HE Hongyan(Tongmei datang tashan NO. 2 power Co. , Ltd, Datong 037000, Chin)
出处 《电工技术》 2018年第8期71-72,共2页 Electric Engineering
关键词 超临界 闭式水泵 轴断裂 疲劳 再循环 处理措施 supercritical closed water pump shaft fracture fatigue recycling treatment measures