期刊文献+

Dynamic model of saturator based on a global heat and mass transfer coefficient 被引量:1

一种基于通用传热传质系统的新型饱和器的动态建模方法(英文)
下载PDF
导出
摘要 Saturator is one of the core components of humid air turbine (HAT) and is the main feature of HAT making it different from other gas turbine cycles. Due to the lack of sufficient experience in commercial plant operation, HAT cycle has a great demand for modeling and simulation of the system and its components, especially the saturator, to provide reference for system design and optimization. The conventional saturator models are usually based on the theory of heat and mass transfer, which need two accurate coefficients to ensure convincing results. This work proposes a global heat and mass transfer coefficient based on cooling tower technology to model the saturator in small-scale HAT cycle. Compared with the experimental data, the simulation results show that the proposed model well predicts the dynamic humidity and temperature distribution characteristics of saturator at low air pressure and temperature. 饱和器是湿空气透平(HAT)循环最重要的部件之一,也是HAT循环与其他燃气轮机循环最重要的区别。由于缺少相关商业运行的经验,热力系统建模与仿真,特别是对饱和器的建模、仿真工作,对HAT循环系统设计、优化有着至关重要的意义。传统饱和器模型通常是基于传热传质理论,该理论需要精确的传热系数和传质系数来保证模型的准确性。本文提出了一种利用基于冷却塔模型的通用传热传质系数来描述小型HAT循环系统中饱和器的建模方法。通过与仿真结果的比较表明,该模型可以很好地预测饱和器在低压低温条件下的内部湿度和温度的动态分布特性。
出处 《Journal of Central South University》 SCIE EI CAS CSCD 2018年第5期1173-1181,共9页 中南大学学报(英文版)
基金 Project(2017YFB0903300)supported by National Key R&D Program of China Project(2016M601593)supported by China Postdoctoral Science Foundation
关键词 SATURATOR cooling tower technology global coefficient dynamic modeling 饱和器 冷却塔模型 通用系数 动态建模
  • 相关文献

参考文献3

二级参考文献20

  • 1肖云汉,林汝谋,蔡睿贤.HAT循环的系统优化[J].工程热物理学报,1994,15(2):133-136. 被引量:9
  • 2徐震,王渺林,王岳,肖云汉.喷嘴雾化对湿化器内空气加湿过程的影响[J].热力发电,2006,35(4):38-41. 被引量:5
  • 3PARENTE J, TRAVERSO A, MASSARDO A F. Micro humid air cycle part A: thermodynamic and technical aspects [ R]. ASME Paper, 2003 - GT - 38326,2003.
  • 4THERN M, LINDQUIST T,TORISSON T. Theoretical and experimental evaluation of a plate heat exchanger aftercooler in an evaporative gas turbine cycle[ R ]. ASME Paper, 2003 - GT - 38099, 2003.
  • 5Gate Cycle User' s Guide[ R]. GE - Enter Software Inc,2003.
  • 6ZHANG S J, XIAO Y H. Steady - state off - design thermodynamic performance analysis of a humid air turbine based on a micro turbine [ R ]. ASME Paper, GT - 2006 - 90335,2006.
  • 7WANG B,ZHANG S J, XIAO Y H. Steady - state off - design performance of humid air turbine cycle[ R]. ASME Paper, GT -2007 - 27350,2007.
  • 8PARENTE J, TRAVERSO A, MASSARDO A F. Saturator analysis for an evaporative gas turbine cycle [J]. Applied Thermal Engineering, 2003, 23: 1275- 1293.
  • 9LINDQUIST T,THERN M, TORISSON T. Experimental and theoretical results of a humidification tower in an evaporative gas turbine cycle pilot plant [ R ]. ASME Paper, GT - 2002 - 30127, 2002.
  • 10Kloppers J C,Kroger D G,The Lewis Factor and its influence on the performance prediction of wet - cooling towers, International Journal of Thermal Science, 2005 (44) : 879 - 884.

共引文献4

同被引文献7

引证文献1

二级引证文献2