期刊文献+

小径管焊缝X射线数字成像检测与相控阵成像检测技术对比 被引量:5

Comparison of X-Ray Digital Imaging Detection and Phased Array Imaging Detection Technique of Small Diameter Tube Welds
下载PDF
导出
摘要 在射线数字平板直接成像(DR)检测技术和相控阵(PA)检测技术的理论基础上,通过对几种不同规格的小径管焊缝典型缺陷的检测对比来研究这两种新技术的差异,可看出DR技术和PA技术均能检出相关缺陷,总体来看,PA技术检出的缺陷长度略大一些。由于PA技术具有三维、3D成像等特点,其图像显示缺陷的信息更多,除了缺陷长度外,还能显示在基准灵敏度下的幅值、缺陷的自身高度,且通过设置焊缝坡口参数可实现3D动态成像,可更直观显示缺陷位置;而DR技术形成的缺陷形状更直观,更便于缺陷定性。 According to the principle of director digital panel radiography(DR)technique and ultrasonic phased array(PA)technique,the difference between these two new techniques can be obtained by comparing the typical defects of several different sizes of small diameter pipe welds.It can be concluded that DR technique and PA technique can detect the relevant defects on the whole,whereas the defect length given by PA was slightly oversized.As the PA technique is characteristic of 3D imaging,so its image display of defect can give more information.In addition to the length of the defect,the PA image also shows the amplitude of the reference sensitivity,the height of the defect,and it can achieve 3D dynamic imaging through setting the weld groove parameters,thus resulting in more intuitive display of defect location.On the other hand,the DR technique is to form more intuitive defect shape,and is easier to qualify the defect.
作者 王景人 支泽林 靳超 WANG Jingren;ZHI Zelin;JIN Chao(Shaanxi boiler and Pressure Vessel Inspection Institute, Xi'an 710048, China;Beijing Zouzhan Lucheng Science and Technology Co., Ltd., Beijing 100034, China)
出处 《无损检测》 2018年第4期30-35,40,共7页 Nondestructive Testing
关键词 小径管 X射线数字成像技术 相控阵检测技术 对比 small diameter tube DR technique PA technique comparison
  • 相关文献

参考文献3

二级参考文献18

  • 1单洪彬,李明,陈怀东,吕天明.国外超声检测仿真软件的研究进展[J].无损检测,2008,30(7):446-450. 被引量:17
  • 2Casula O, Poidevin C, Cattiaux G, et al. Control of complex components with smart flexible phased arrays [ J ]. Ultrasonics, 2006, 44 (SI) : e647 - e651.
  • 3Chatillon S, Cattiaux G, Serre M, et al. Ultrasonic non - destructive testing of pieces of complex geometry with a flexible phased array transducer[ J]. Ultrasonics, 2000, 38 (1 -8) : 131 - 134.
  • 4Raphaele R, lsabelle L T. Transient elastodynamic model for beam detect interaction application to non -destructive testing [ J ]. Ultrasonics, 2000, 38 ( 1 - 8) : 527 - 530.
  • 5Lhemery A, Calmon P, Chatillon S, et al. Modeling of ultrasonic fields radiated by contact transducer in a component of irregular surface [ J ]. Ultrasonics, 2002, 40( 1 - 8 ) : 231 - 236.
  • 6Long R, Cawley P. Phased array inspection of irregular surfaces [ C ]//Review of progress in quantitative nondestructive evaluation.Portland : American Institute of Physics, 2007.
  • 7Puel B, Lesselier D, Chatillon S, et al. Optimization of ultrasonic arrays design and setting using a differential evolution [ J ]. NDT & E International. 2011, 44(8) : 797 -803.
  • 8施克仁,郭寓岷.相控阵超声波成像检测[M].北京:高等教育出版社,2010.
  • 9Hunter A J, Drinkwater B W, Wilcox P D. Autofocusing ultrasonic imagery for non - destructive testing and evaluation of specimens with complicated geometries [ J ]. NDT & E International: Independent Nondestructive Testing and Evaluation. 2010, 43 (2) : 78 -85.
  • 10桂朝伟,唐晓薇,翟俊鹏,崔彦青.碘化铯非晶硅平板探测器的原理及应用[J].中国医学装备,2009,6(9):10-13. 被引量:8