期刊文献+

汉川电厂汽包水位测量存在的问题分析及改进

Analysis on the problems in Drum Water Level Measurement in Han Chuan Power Plant
下载PDF
导出
摘要 汽包水位作为表征锅炉安全运行的重要参数,汽包水位测量的准确性和可靠性是实现汽包水位自动控制的前提,是防止汽包满水、缺水,防止汽轮机进水的重要保证。正确安装、及时检修维护、及时解决存在的问题和故障,是汽包水位测量能够长周期可靠运行的保证。通过对汉川电厂的汽包水位测量存在的问题进行分析,总结了存在的问题,探讨消除偏差的改进措施。 Drum water level is an important parameter to characterize the safe operation of the boiler. The accuracy and reliability of the drum water level measurement is the premise to realizeautomatic control of the drum water level, and is an important guarantee to prevent the drum fromfull of water, water shortage and steam turbine water intake. Correct installation, timely repair andmaintenance, timely solution to the problems, timely troubleshooting, are the guarantee oflong-term reliable operation of the drum water level measurement. The problems existing in thedrum level measurement of Hanchuan Power Plant are analyzed in this paper, the existing problemsare summed up and the improvement measures to eliminate the deviation are discussed.
作者 陈节涛 肖波 卓旭升 吴尔夫 CHEN Jietao;XIAO Bo;ZHUO Xusheng;WU Erfu(GUO DIAN Han Chuan Power Plant Co LTD. ,Hanchuan Hubei 431614,China;Wuhan Institute of Technology,Wuhan Hubei 430205,China)
出处 《湖北电力》 2017年第9期47-49,54,共4页 Hubei Electric Power
关键词 汽包水位测量 偏差分析 差压水位计 改进措施 drum water level measurement differential pressure water level gauge deviation analysis improvement measures
  • 相关文献

参考文献1

二级参考文献7

  • 1孙长生,王建强.浙江省电厂分散控制系统故障原因、处理与建议[J].电力建设,2006,27(2):62-65. 被引量:12
  • 2DL/T774-2004火力发电厂热工自动化系统检修运行维护规程[S].北京:中国电力出版社,2004.
  • 3孙长生.浙江省火电厂锅炉汽包水位测量保护系统运行现状分析及技术措施研究报告[R].杭州:浙江省电力试验研究,2008.
  • 4朱北恒.热工自动化系统试验[M].北京:中国电力出版社,2006.
  • 5侯子良,刘吉川,侯云浩,等.锅炉汽包水位测量系统[M].北京:中国电力出版社,2004:1-6.
  • 6DRZ/T01-2004火力发电厂锅炉汽包水位测量系统技术[S].北京:中国电力出版社,2004.
  • 7杨震力,张龙明,邵军伟.汽包水位测量系统误差分析处理与完善建议[J].自动化博览,2008,25(11):100-103. 被引量:4