期刊文献+

旁通阀式余压控制系统的研究 被引量:1

Research on By-pass Damper Type Positive Pressure Control System
下载PDF
导出
摘要 详细阐述了旁通阀式余压控制系统的组成、工作原理,并结合实际项目实例,分析了平面优化设计方法。提出旁通阀式余压控制系统是通过设在住宅前室的压力传感器来调节加压送风系统在区域的进风量,从而改变区域的风压差,为疏散通道上防火门的顺利开启提供保障,进而保障人员的安全疏散。 The composition and working principle of the by-pass damper type residual pressure control system were described in detail. Combining by an actural project,the plane optimization design method was anayzed. It is pointed out that the by-pass damper type positive pressure control system is used to adjust the wind pressure of the pressurized air supply system through the pressure sensor of dwelling front room,which changes the wind pressure difference in this area. This system provides the guarantee for the smooth opening of fire doors in the evacuation channel,which ensures the safe evacuation of personnel.
作者 朱潋 唐庆 龙宇 ZHU Lian;TANG Qing;LONG Yu(Chengdu JZFZ Architectural Design Co., Ltd., Chengdu 610011, China)
出处 《现代建筑电气》 2018年第4期53-56,共4页 Modern Architecture Electric
关键词 旁通阀式余压控制系统 压力传感器 加压送风系统 住宅前室 by-pass damper type positive pressure control system pressure sensor pressurized air supplysystem dwelling front room
  • 相关文献

参考文献2

二级参考文献7

  • 1民用建筑电气设计规范(JGJ16-2008)[s].北京:中国建筑出版社,2008.
  • 2建筑设计防火规范(GB50016-2006)[S].北京:中国计划出版社.2006.
  • 3建筑防排烟技术规程(DGJ08-88-2006)[S]上海:上海市建设厅,2006.
  • 4全国民用建筑工程设计技术措施·暖通空调·动力[M].北京:中国计划出版社,2009.
  • 5高层民用建筑设计防火规范(GB50045-95)(2005年版)[S].北京:中国计划出版社,2005r5.
  • 6杨晓光.防火门、防火卷帘设计使用存在的问题及对策[J].消防技术与产品信息,2011,24(2):47-49. 被引量:10
  • 7周曙,周锋,罗友权.论防火门的自动控制[J].消防技术与产品信息,2004,17(4):27-29. 被引量:2