摘要
It is difficult to rapidly and on-line detect trace volatile organic compounds for miniature massspectrometry due to its limited sampling volume at slow pumping speed. In this paper, we developed anew radiofrequency field enhanced chemical ionization source (RF-ECI) with vacuum ultraviolet (VUV)lamp by coupling radiofrequency electric field and direct-current field together. The experiment resultsshowed that the sensitivity of benzene, toluene, hydrogen sulfide and other compounds increased by 2-3orders of magnitude under the introduction of RF-ECI comparing to traditional single photon ionization(SPI). At the same time, the reagent ion of O2+ realized the charge transfer reaction chemical ionization,and the RF-ECI effectively expanded the detection range of the VUV lamp based SPI. The VUV lamp hasinherent advantages in the on-site analytical instrument for its small size and low power consumption,and the VUV lamp based RF-ECI miniature time-of-flight mass spectrometer (TOFMS) has a limit-of-detection for H2S as low as 0.0571 mg/m3, and it is expected to be used widely in the field of on-site rapidanalvsis.
It is difficult to rapidly and on-line detect trace volatile organic compounds for miniature massspectrometry due to its limited sampling volume at slow pumping speed. In this paper, we developed anew radiofrequency field enhanced chemical ionization source (RF-ECI) with vacuum ultraviolet (VUV)lamp by coupling radiofrequency electric field and direct-current field together. The experiment resultsshowed that the sensitivity of benzene, toluene, hydrogen sulfide and other compounds increased by 2-3orders of magnitude under the introduction of RF-ECI comparing to traditional single photon ionization(SPI). At the same time, the reagent ion of O2+ realized the charge transfer reaction chemical ionization,and the RF-ECI effectively expanded the detection range of the VUV lamp based SPI. The VUV lamp hasinherent advantages in the on-site analytical instrument for its small size and low power consumption,and the VUV lamp based RF-ECI miniature time-of-flight mass spectrometer (TOFMS) has a limit-of-detection for H2S as low as 0.0571 mg/m3, and it is expected to be used widely in the field of on-site rapidanalvsis.
基金
financially supported by the National Natural Science Foundation of China(Nos.21375129 and 21675155)