摘要 应急柴油发电机组是保障核电站安全运行的重要安保电源设施。润滑油系统是核电站应急柴油发电机组重要辅助系统之一,在机组备用状态下即投入运行,并在机组起动后持续运行,必须具有很好的安全性能和可靠性。通过分析润滑油系统的设计功能与性能要求,将润滑油系统总体划分为三个子系统,并对系统设备的安全等级进行划分,完成了系统的设计方案。结合现役核电站的经验反馈,在润滑油系统设计方案中增加了预润滑油泵双泵冗余设计和PCOT监测技术,保障了核电站应急柴油发电机组的安全稳定运行。 Emergency diesel generator set is an important security power supply to ensure the safe operation of nuclear power station. As one of the important auxiliary system for emergency diesel generator set in nuclear power station, the lubricating oil system which must be durable and reliable is put into operation in the standby state, and it will continue to run after the unit is started. By analyzing the design function and performance requirements of the lubricating oil system and the division of safety grade, the main design requirements are defined. According to the function and performance requirements, the lubricating oil system is divided into three subsystems, and the design scheme is completed. Combined with the experience and feedback from nuclear power plants in active service, the redundant design of pre-lubricating oil pump and PCOT monitoring technology are added to the design scheme, which ensure the safe and stable operation of emergency diesel generator set in nuclear power station.
作者 殷勇 吴腾 艾华宁 于江 YIN Yong;WU Teng;AI Huaning;YU Jiang(China Nuclear Power Technology Research Institute, Shenzhen 518031, China)
出处 《大电机技术》 2018年第3期71-74,共4页 Large Electric Machine and Hydraulic Turbine
基金 国家能源局应用技术研究及工程示范项目(NY20140203)
关键词 核电站 应急柴油发电机组 润滑油系统 双泵冗余 PCOT nuclear power station emergency diesel generator set lubricating oil system double pump redundancy PCOT
  • 相关文献

参考文献10

二级参考文献13

  • 1郭朝辉,吴帆.核电电气设备安全分级简介[J].电力安全技术,2008,10(6):69-70. 被引量:2
  • 2康慧,王伟.核电厂核级机械设备安全分级[J].电力勘测设计,2007,19(2):67-70. 被引量:3
  • 3孙培延,李斌,杜荣铭.船舶柴油机[M].大连:大连海事大学出版社,2006:114-118.
  • 4IAEA.Safety Classification of Structures,Systems and Com-ponents in Nuclear Power Plants. IAEA SAFETY STAN-DARDS.Draft DS367 . 2008
  • 5ANSI/ANS.Nuclear Safety Criteria for the Design of Stationary Pressurized Water Reactor Plants. . 1983
  • 6耿文行,赵月扬.法国CP1-CP2系列核电机组安全重要设备分级的经验反馈[J].核安全,2007,6(1):42-48. 被引量:8
  • 7GU620-柴油发电机控制器通信协议[S].广州凯讯公司.
  • 8GB2820—1997,往复式内燃机驱动的交流发电机组[S].
  • 9GB/T21428-2008,往复式内燃机组驱动的发电机组安全性[S].
  • 10IEEE387-1995,核电厂备用电源柴油发电机组标准[S].

共引文献33

同被引文献8

引证文献2

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部