期刊文献+

胎儿脐血流和大脑中动脉参数在羊膜腔灌注中的对比分析 被引量:1

Comparison between fetal umbilical cord blood flow parameters and middle cerebral artery peak systolic velocity in amniotic infusion therapy for oligohydramnios
下载PDF
导出
摘要 目的对比羊膜腔灌注前后,羊水过少胎儿脐血流参数及大脑中动脉峰值流速变化,以了解羊膜腔灌注治疗对胎儿脐带及大脑中动脉血流的影响。方法选择2014-01~2016-12羊水过少妊娠22~33周的孕妇18例,进行羊膜腔灌注,比较羊膜腔灌注前后的羊水指数(AI)及脐血流参数、胎儿大脑中动脉峰值流速(MCA-PSV)的变化。结果羊膜腔灌注术后AI明显增加,S/D比值下降,差异有统计学意义(P<0.01);羊膜腔灌注术后阻力指数(RI)下降,差异有统计学意义(P<0.05);MCA-PSV略有上升,但差异无统计学意义。结论羊膜腔灌注可以短时间明显增加羊水量,改善胎儿脐血流,对胎儿大脑中动脉峰值流速无影响。 Objective To compare the changes of umbilical cord blood flow parameters and the middle cerebral artery peak systolic velocity before and after the amniotic infusion therapy,and to explore the effect of amniotic infusion therapy on fetal umbilical cord blood flow and middle cerebral artery peak systolic velocity( MCA-PSV) in oligohydramnios. Methods 18 pregnant women who had been diagnosed with oligohydramnios by sonography between22 and 33 gestational weeks received amniotic infusion in our department from January 2014 to December 2016. The amniotic fluid index( AI),umbilical blood flow parameters such as S/D,RI and middle cerebral artery peak systolic velocity( MCA-PSV) were recorded and compared before and after amniotic infusion. Results The amniotic fluid index was improved significantly( P〈0. 01),S/D and RI were both decreased significantly( P〈0. 01,P〈0. 05) after amniotic infusion,but MCA-PSV was not markedly changed. Conclusion Amniotic infusion therapy can improve amniotic fluid index and umbilical artery flow parameters in a short period,but has no effect on the peak systolic velocity of the middle cerebral artery.
作者 覃婷 田矛 张继红 伍欣 QIN Ting;TIAN Mao;ZHANG Ji-hong(Department of Obstetrics,the People's Hospital of Guangxi Zhuang Autonomous Region,Nanning 530021,China)
出处 《中国临床新医学》 2018年第5期430-432,共3页 CHINESE JOURNAL OF NEW CLINICAL MEDICINE
基金 广西卫计委科研课题(编号:Z2013349)
关键词 羊膜腔灌注 羊水过少 羊水指数 大脑中动脉峰值流速 收缩期最大血流速度与舒张末期最小血流速度比值 Amniotic infusion Oligohydramnios Amniotic fluid index" AI) Middle cerebral arterypeak systolic velocity(MCA-PSV) Systolic/diastolic ratio" ^^D)
  • 相关文献

参考文献5

二级参考文献32

  • 1刘辉英,廖绮琳,王秋菊,陈梅英.复方丹参注射液治疗妊娠晚期羊水过少100例临床观察[J].哈尔滨医药,2004,24(5):27-27. 被引量:29
  • 2叶光勇,李爱云.羊水过少孕妇血液流变学指标变化及其围生儿预后[J].实用妇产科杂志,2005,21(4):248-249. 被引量:13
  • 3SheUhaas CS, Coffman T, Dargie PJ, et al. Intravillous e- icosanoid compartmentalization and regulation of placental blood flow [J]. J Soc Gynecol Invest. 1997,4(2):58-63.
  • 4Chavarria Olarte ME, Gonz(dez Gleason A, Lara Gonz(dez AL,et al. Plasma concentration of biochemical mazke~ in pre eclampsi- aeclampsia and its association with the severity of the disease [J]. Ginecol Obstet Mex, 2000,68:385 - 393.
  • 5Magann EF, Doherty DA, C hauhan SP, et al. Effect of maternal hydration on amniotic fluid volume. Obstet Gynecol, 2003, 101 (6) : 1261 - 1265.
  • 6FlackN J, SepulvedaW, Bower S, et al. Acutematemal hydration in third-trlm ester olig-ohydramnios: effects on amniotic fluid vol- ume,uter placental perfu~ion, and fetal blood flow and urine out- put. Am J ObstetGynecol, 1995,173(4) : 1186 - 1191.
  • 7Francisco RP,Miyadahira S,Zugaib M. Predicting pH at birth arteries absent or reversed end-diastolic velocity in the um- bilical arteries[ J]. Obstet and Gynecolo, 2006, 107 ( 11 ) : 1 042-1 047.
  • 8Hofstaetter C, Gudmundsson S, Hansmann M. Venous Doppler velocimetry in the surveillance of severely compromised fetuses [J]. Ultrasound Obstet Gynecol,2002,20(3) :233 -239.
  • 9DeVore GR,Horenstein J. Ductus venosus index:a method for evaluating right ventricular preload in the s.econd-trimester fe- tus[J]. Ultrasound Obstet Gynecol,1993,3(5) :338 -342.
  • 10Carvalho FH, Moron AF, Mattar R, et al. Ductus venosus Doppler velocimetry to predict acidemia at birth in pregnan- cies with placental insufficiency [ J ]. Rev Assoc Med Bras, 2005,51 (4) :221 -227.

共引文献26