膨胀机启动后就地转速表和DCS画面均无转速值显示,分析其原因是转速传感器与被测转轴间距离过大,无法检测到被测转轴转速,调整转速传感器后问题得以解决。
There was no speed rotate display on local instrument and DCS when the expander started. Analysis showed that the distance between speed transmitter and measured spindle was too large, and the rotation speed of the measured shaft could not be detected. This problem could be solved by readjust of the speed sensor.
作者
杨雪莲
鲁浩
YANG Xuelian;LU Hao(Hangzhou Hangyang Co. , Ltd. Petrochemical Engineering Company, Hangzhou 31004, China;State Nuclear Power Automation System Engineering Company, Shanghai, China)
出处
《电工技术》
2018年第7期49-49,51,共2页
Electric Engineering
关键词
膨胀机
转速
异常
expander
rotate speed
abnormal