装配式剪力墙竖向焊接节点抗剪性能 被引量:10

Shear Behavior of Vertical Welded Connection in Precast Shear Wall
下载PDF
导出
摘要 为了对装配式剪力墙结构节点干式连接方案进行研究,在已有研究成果新型预制复合墙板体系的基础上提出了采用焊接连接的装配式剪力墙干式节点方案,并通过两批共5个焊接节点试件的单调静力加载试验来考察竖向节点的抗剪性能和变形能力.试验表明,节点试件具有较好的抗剪性能和变形能力;试件破坏始于节点周围区混凝土出现裂缝,终于连接钢板和锚筋剪断致使节点试件失去承载能力.在此基础上通过ABAQUS有限元分析软件对节点试件受力过程进行了模拟,并对各种材料参数进行了详细比较和分析.通过比较可知该类节点抗剪性能和变形能力主要由连接钢板、锚筋抗剪承载力和节点周围区混凝土抗压承载力决定,纵筋、箍筋、预埋钢板等材料参数变化对节点试件影响不大.最终,得到了竖向节点焊接连接方案可用于装配式剪力墙结构节点连接之中的结论. To study the dry connections in precast shear wall structure,this paper presented a welded connection approach for precast shear wall vertical joint based on an existing advanced prefabricated composite wall system.By manufacturing and testing 5 specimens under monotonic static loadings,the shear pattern and deformability of the dry connection were studied.The results showed that the welded connection has a good shear patterns and deformability.The failure of the specimens began with the concrete cracks around the joints,and shear failure ultimately occurred in the connecting steel plates and anchor bars.Then,detailed analysis and comparison of material parameters were conducted by using finite element analysis software ABAQUS.It was observed that shear pattern of the welded connection was mainly determined by shear resistance of connecting steel plates,shear resistance of anchor bars,and compressive resistance of the concrete around pre-embedded steel plate,while longitudinal reinforcement,stirrup and pre-embedded steel plate had limited impact.It is concluded that this welded connection approach can be utilized for the vertical joint of precast shear wall.
作者 徐咏 熊峰 陈江 XU Yong;XIONG Feng;CHEN Jiang(School of Architecture and Environment,Sichuan University,Chengdu 610065,China)
出处 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2018年第5期53-61,共9页 Journal of Hunan University:Natural Sciences
基金 国家重点研发计划专项资助项目(2016YFC0701400) 四川省科技支撑计划项目(2015FZ0080)~~
关键词 装配式剪力墙 竖向节点 焊接连接 单调加载静力试验 数值分析 precast shear wall vertical joints welded connections monotonic loading static test numerical analysis
  • 相关文献

参考文献6

二级参考文献59

  • 1严薇,曹永红,李国荣.装配式结构体系的发展与建筑工业化[J].重庆建筑大学学报,2004,26(5):131-136. 被引量:172
  • 2JGJ101-1996,建筑抗震试验方法规程[S].北京:中国建筑工业出版社,1997
  • 3GB50011-2010建筑抗震设计规范[S].北京:中国建筑工业出版社,2010.
  • 4GB50010-2010,混凝土结构设计规范[s].北京:中国建筑工业出版社.2010.
  • 5Zhang Jichao, Gao Junwei, Wang Keyi, et al. Experimental study on the falling slab node of the new concrete superposed floor slab [ C ]// 3th International Conference on the Concrete Future. Yantai: Yantai University Press ,2008:501-508.
  • 6Zhang Jichao, Li Nan, Wang Keyi, et al. Experimental study on seismic behaviour of pre-cast concrete beam- column sub-assemblage with cast-in-situ monolithic joints [ C ]// 3th International Conference on the Concrete Future. Yantai : Yantai University Press, 2008:509-518.
  • 7Zhang Jichao, Qiu Jianhu, Chen Yuan, et al. Experimental study on the new composite beam-column frame exterior joints [ C ]//3th International Conference on the Concrete Future. Yantai: Yantai University Press,2008 : 519-525.
  • 8Zhang Jichao, Liu Bo, Wang Keyi, et al. Experimental research on the key joints of the assembled and integral reinforced concrete structure [ C ]// 3th International Conference on the Concrete Future. Yantai: Yantai University Press, 2008:526-531.
  • 9GB50010-2010混凝土结构设计规范[S].北京:中国建筑工程出版社,2011.
  • 10JGJ3-2010高层建筑混凝土结构技术规程[S].北京:中国建筑工业出版社,2011.

共引文献188

同被引文献114

引证文献10

二级引证文献35

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部