期刊文献+

门窗执手操作力的测量不确定度评定 被引量:1

Measurement Uncertainty Evaluation of the Operating Force for Win-Door Handle
下载PDF
导出
摘要 门窗执手操作力测试装置是动态测试执手在开启和关闭过程中的操作力,要求测量器具的受力方向始终与执手手柄中心线的竖直平面保持垂直。针对门窗执手操作力测试装置的工作特点,从执手轴心与驱动臂轴心同轴、施力位置测量误差、传感器受力支点垂直度、测量重复性、力值误差等方面引入的不确定度进行了分析和探讨,可为同类五金产品操作力测量不确定度的评定提供参考。 The win-door handle operating force test device is the operating force of the dynamic test handle during opening and closing. It is required that the force direction of the measuring appliance always be perpendicular to the vertical plane of the handle centerline. In this paper, according to the operating characteristics of the win-door handle operating force test device, we discussed and analyzed the uncertainty caused by the axial force of the hand axis and the shaft of the actuating arm,the measuring error of the force position,the vertical degree of the sensor,the measurement repeatability,the force value error,etc,which can provide a reference for the evaluation of measurement uncertainty to the similar hardware products operating force.
作者 高康 欧阳壮 魏承炀 汪志杰 GAO Kang;OUYANG Zhuang;WEI Cheng-yang;WANG Zhi-jie(National Center of Supervision and Inspection for Architectural Hardware (Guangdong),Zhaoqing 526000,Chin)
出处 《机电工程技术》 2018年第5期167-169,共3页 Mechanical & Electrical Engineering Technology
基金 广东省质量技术监督局科技计划项目(编号:2015PZ01) 广东省肇庆市高新技术产业和战略性新兴产业专项资金项目(编号:2013B0300002)
关键词 门窗执手 动态垂直测力 测量不确定度 win-door handle;dynamic vertical force measurement;measurement uncertainty
  • 相关文献

参考文献1

二级参考文献5

  • 1赵家瑞.关于电器产品检测不确定度相关问题的探讨(二)[J].家电科技,2004(10):71-74. 被引量:3
  • 2.JJF1059-1999,测量不确定度评定与表示[S].北京:计量出版社,2000..
  • 3王克勤.不确定度在检测实验室的应用[M]..安全与电磁兼容[C].中国电子技术标准化研究所,2001..
  • 4杨世元 吴国平.电器质量检测不确定度[M].北京:中国标准出版社,2002..
  • 5李慎安.测量误差及数据处理技术规范解说[M].北京:中国计量出版社,1996..

共引文献13

同被引文献1

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部