期刊文献+

电感耦合等离子体发射光谱法测量土壤中有效锌含量的不确定度评估 被引量:6

Evaluation of measurement uncertainty in determining available zinc in soil by inductively coupled plasma optical emission spectrometry
下载PDF
导出
摘要 对电感耦合等离子体发射光谱法(ICP-OES)测定土壤有效锌含量的不确定度进行评定,分析了整个检测过程产生不确定度的来源,对称样量、浸提液体积、标准系列溶液配制、线性标准曲线拟合、测量重复性等产生的不确定度分量进行计算,量化给出扩展不确定度。待测土壤中有效锌含量最终结果表示:w(Zn)=(1.12±0.10)mg/kg,包含因子k=2,置信概率为95%。测量过程中,标准溶液制备所产生的不确定度最大。因此,在ICP-OES法测定土壤样品有效锌时应足够重视标准溶液制备与曲线拟合过程,以减小测量不确定度。本文研究结果为控制ICP-OES法测定土壤有效锌数据质量提供了理论依据。 Available zinc( Zn) in soil is widely extracted by DTPA( diethylenetriaminepentaacetic acid) solution. Zn concentration in the extract is increasingly determined by ICP-OES( inductively coupled plasma optical emission spectrometry)technique. The uncertainty in measurement of soil available Zn by ICP-OES method was evaluated. The sources of uncertainty in the testing process including sample weight,extract volume,Zn standard solution series preparation,linear standard curve fitting and measurement repeat were quantified dividedly. The expand uncertainty was calculated and the results of soil available Zn determined by ICP-OES method was then conveniently expressed as w( Zn) =( 1. 12 ± 0. 10) mg/kg,a coverage factor k = 2. A confidence interval of 0. 10 mg/kg at probability 95% level was suggested for the measurement of soil available Zn by ICP-OES. The greatest uncertainty of measurement might result from Zn standard solution series curve preparation. It suggested more attention should be paid on the preparation process of Zn standard solution and curve fitting to reduce the measurement uncertainty in the determination of soil available Zn by ICP-OES.
作者 刘蜜 范洪黎 柴晓 李桂花 汪洪 LIU Mi, FAN Hong-li, CHAI Xiao, LI Gui-hua, WANG Hong(Key Laboratory of Plant Nutrition and Fertilizer, Ministry of Agriculture/Institute of Agricultural Resources and Regional Planning, Chinese Academy of Agricultural Sciences, Beijing 100081)
出处 《中国土壤与肥料》 CAS CSCD 北大核心 2018年第2期170-175,共6页 Soil and Fertilizer Sciences in China
基金 国家重点研发计划项目(2016YFD0200108) 中央级公益性科研院所基本科研业务费专项(Y2017PT14 720-69)
关键词 电感耦合等离子体发射光谱法 土壤有效锌 不确定度 inductively coupled plasma optical emission spectrometry soil available zinc uncertainty of measurement
  • 相关文献

参考文献4

二级参考文献17

  • 1国家质量技术监督局计量司.测量不确定度评定与表示指南[M].北京:中国计量出版社,2000.62-124.
  • 2国家质量技术监督局.测量不确定度评定与表示[S].JJFl05921999.北京:中国计量出版社,1999.
  • 3国家质量监督检验检疫总局.化学分析测量不确定度评定[S].JJF113522005.北京:中国计量出版社,2005.
  • 4中华人民共和国林业标准.森林土壤中有效铜的测定[S].LY/T 1260-1999.北京:中国标准出版社,1999.2.
  • 5中华人民共和国林业标准.森林土壤中有效锌的测定[S].LY/T 1261-1999.北京:中国标准出版社,1999.2.
  • 6中华人民共和国国家计量检定规程.《测量不确定度评定与表示》理解与应用[S].JJG 196-2006.北京:国家质量监督检验检疫总局,2007.
  • 7杭州大学化学系分析化学教研室.分析化学手册(第二分册)/化学分析[M].北京:化学工业出版社,1982.38-40.
  • 8JJF1059—1999.测量不确定度评定与表示.[S].,..
  • 9中国实验室国家认可委员会.化学分析中不确定度的评估指南[M].北京:中国计量出版社,2000..
  • 10GB/T17138—1997.土壤质量铜、锌的测定.[S].,..