现浇成型墙体养护周期长,极大影响施工效率。本文通过对不同养护条件下非均质材料传热系数的检测结果进行分析,总结出一个快速检测墙体传热系数方法,在保证建筑节能质量的同时提高施工效率,缩短施工周期。
The cast-in-place wall has a long curing period,which greatly affects the construction efficiency. This paper analyzes the test results of the thermal transmittance of heterogeneous materials under different curing conditions,and summarizes a method for rapid testthe thermal transmittance ofwall,which can improve construction energy efficiency,improve construction efficiency,and shorten construction period.