摘要 本文首先分析了辐照箱故障现状, 然后探讨故障产生的原因, 并从改进焊缝设计、 改进结构设计和规范货物装载方式等方面提出辐照箱故障改进措施, 最后对改进前后进行对比.通过对比可知: 改进效果明显, 故障率始终控制在5.3%以内, 有效保证了产品质量. This paper first analyzed the failure status of the irradiation box, then discussed the causes of the failure, and puts forward the improvement measures of the irradiation box from aspects of improving the weld design, improving the structural design and standardizing the loading way. Finally, the comparison was made before and after the improvement. Through comparison, it was clear that the improvement effect is obvious, the failure rate was always controlled within 5.3%, and the quality of the product was guaranteed effectively.
作者 牛翼 黄天亮 杜高刚 NIU Yi;HUANG Tianliang;DU Gaogang(Equipment Manufacturing Plant , Nuclear Power Institute of China,Chengdu Sichuan 610005)
出处 《河南科技》 2018年第7期61-62,共2页 Henan Science and Technology
关键词 辐照箱 质量控制 在线使用率 irradiation box;quality control;online usage
  • 相关文献

参考文献2

二级参考文献5

  • 1卫生部卫生法制与监督司 公安部三局.全国放射事故案例汇编[M].北京:中国科学技术出版礼,2001,1..
  • 2侯庆梅 孙晓博.1985—1994年τ辐照装置放射事故原因浅析[J].中国辐射卫生,1997,6(1):16-18.
  • 3IAEA.工业辐照装置的事故教训[M].北京:原子能出版社,1999.
  • 4国家环境保护总局.关于山东济宁放射源超剂量照射事故有关情况的通报[Z].环办[2004]99号.
  • 5王嘉璐.我省开展辐照装置运营单位安全专项检查[EB/OL].http://www.lnepb.gov.cn/look.asp id={F3809281-0266-434F-B283-732B33C856D7},2005-03-10/2005-08-01.