大量程压力变送器受压薄弱部位的强度设计

Weak Area of Compression Strength Design in Terms of Large Range Pressure Transmitters
下载PDF
导出
摘要 从大量程压力变送器工作原理入手,对其机械部总组件进行整体结构的受力分析,通过构造力学模型、确定受压薄弱部位满足的强度条件,转换成包含壁厚、熔深等物理量的数学关系式,计算出具体尺寸数值,为强度设计提供可靠依据。此设计方法对其它高压压力容器、管道的强度设计具有一定的借鉴和指导意义。 First of all, this paper Introduces the working principle of large range pressure transmitters, Analyzes the force of general assembly of mechanical parts By structuring mechanical model and determining the strength condition that the weak part satisfies, the paper gets the mathematical relationship between wall thickness and weld penetration, calculates specific size values. This strength design is quite reliable. It has certain reference and guiding significance in high pressure vessel and pipe strength design.
出处 《中国仪器仪表》 2018年第5期58-62,共5页 China Instrumentation
关键词 大量程 薄弱部位 强度设计 壁厚 熔深 Large range Weak area Strength design Wall thickness Weld penetration