期刊文献+

基于傅里叶变换红外光谱技术垃圾焚烧烟气在线监测 被引量:8

On-line Monitoring of Waste Incineration Flue Gas Based on Fourier Transform Infrared Spectroscopy
下载PDF
导出
摘要 介绍1套基于傅里叶变换红外光谱技术(FTIR)的垃圾焚烧烟气在线监测装置。利用FTIR解决多组分气体同时定性与定量分析测量,具有非常重要的意义。基于最小二乘法拟合扣除水汽吸收光谱算法是根据标准的吸收光谱,快速拟合出各个组分的吸收光谱,扣除的光谱吸光度与浓度关系成线性关系,相关性达到0.9 99以上。系统经过长时间测量,各组分气体零点漂移都小于1%F.S,其中SO_2、NO_2、HCl、HF稳定性非常好,其标准方差均小于0.1ppm,6组分气体测量结果均足够满足应用条件。 This article introduces a set of on-line monitoring device of waste incineration flue gas based on Fourier transform infrared spectroscopyIt is of great significance to use FTIR to solve the simultaneous qualitative and quantitative measurement of multicomponent gases. The absorption spectrum algorithm of removing hydrosphere based on least square method is fitting the spectra of each component quickly based on the standard absorption spectrum. The relationship between deduction of spectral absorbance and concentration is linear, and the correlation is over 0.999 After a long period of measurement, the zero drift of each component gas is less than 〈1%F.S, especially the stability of 802, NO2, HCl and HF is show well among component gas and standard deviation of them is less than 0.1ppm. The six component gas measurement results are enough to meet the application conditions.
出处 《中国仪器仪表》 2018年第5期63-66,共4页 China Instrumentation
关键词 傅里叶变换红外光谱技术 垃圾焚烧 光谱测量 Fourier Transform Infrared Spectroscopy Waste incineration Spectrum measurement
  • 相关文献

参考文献3

二级参考文献23

  • 1董凤忠,刘文清,刘建国,涂兴华,张玉钧,齐峰,谢品华,陆亦怀,汪世美,王亚萍,魏庆农.机动车尾气的道边在线实时监测(下)[J].测试技术学报,2005,19(3):237-244. 被引量:12
  • 2巫晓丽,范东栋,王平.空间大气成分探测傅立叶变换红外光谱仪[J].航天返回与遥感,2007,28(2):15-20. 被引量:12
  • 3徐亮,刘建国,高闽光,陆亦怀,刘文清,魏秀丽,张天舒,刘志明.开放光程FTIR测量大气甲烷及其与点采样仪器的结果对比[J].红外技术,2007,29(4):239-242. 被引量:8
  • 4GRABER W K,AUBENBERGER R T.Atmospheric trace gas measurements by Differential Optical Absorption Spectroscopy(DOAS):intercomparison with conventional techniques. . 1989
  • 5SANDRONI S,CERUTTI C,NORIEGA A,et al.Air quality measurements in Brussels(1993-1994). European Commission Report EUR16091EN .
  • 6Institute for Environmental Protection and Power Technology.Report on the suitability tests of the OPSIS AR500measuring system for ozone marketed by Opsis AB,Furulund. . 1999
  • 7MCERTS,Sira Certification Service.Product conformity certifi-cate-AR500open path monitor:Sira MC040048/00. . 2004
  • 8Institute for Environmental Protection and Power Technology.Report on the suitability test of the AR602Z multi-constituent measuringsystem for SO2,NO and NO2marketed by OPSIS AB,Furulund/Sweden. . 1991
  • 9Institute for Environmental Protection and Power Technology.Report on the exemplary performance test of the multi-component emission measuring system OPSIS AR602Z of OPSIS AB,Furu-lund/Sweden,for metallic mercury. . 1994
  • 10Institute for Environmental Protection and Power Technology.Report on the suitability test of the AR602Z multi-constituent measuringsystem for NH3marketed by OPSIS AB,Furulund/Swe-den. . 1992