期刊文献+

350 MW超临界CFB机组厂用电率优化分析 被引量:1

Electricity Rate Optimization Analysis of Hepo Power Generation 350 MW Supercritical CFB Unit
下载PDF
导出
摘要 降低机组厂用电率是燃煤电厂节能降耗的重要内容之一,也是提高发电企业经济效益的有效手段。根据河坡发电公司2×350 MW超临界CFB机组各系统实际运行工况,从运行优化和设计优化角度分析节能效果,提出了降低厂用电率的调整措施,量化各因素节能空间并分析该公司超低厂用电率,提高企业经济效益。 Reducing power plant unit power consumption is one of the important parts of energy saving in coal-fired power plants. It is also an effective way to improve the economic efficiency of power generation companies. According to the actual operating conditions in each system 2×350 MW supercritical CFB unit in Hepo power plant,the energy saving effect is analyzed from the perspective optimal operation and design reformation. The adjustment measures to reduce the power consumption rate of the plant are proposed and summarized. It reduces power consumption rate and improves economic efficiency of enterprises.
作者 张文元 ZHANG Wenyuan(Shanxi International Energy Co., Ltd., Taiyuan, Shanxi 030002, Chin)
出处 《东北电力技术》 2018年第4期17-20,共4页 Northeast Electric Power Technology
关键词 CFB机组 厂用电率 优化分析 CFB unit power consumption rate optimization analysis