期刊文献+

7.63m焦炉PROven系统固定杯的固定杆改进 被引量:1

Improvement on the fixing rod of fixing cup of PROven system of 7.63m coke oven
下载PDF
导出
摘要 7.63m焦炉PROven系统中固定杯的固定杆多次发生断裂情况,导致炭化室负压无法实现自动控制。通过研究分析发现,摩损和腐蚀是断裂的主要因素,改进后固定杆稳定性增加,振动幅度降低,磨损减少,有效避免了固定杆发生断裂的情况。 The fixing rod of fixing cup of PROven system of 7.63 m coke oven has broken several times,causing negative pressure in the coking chamber. As a result,the system cannot be controlled automatically. Through study and analysis,it is observed that the main factors causing the breakage is abrasion and corrosion. After improvement,the fixing rod is more stable,with slight vibration and less abrasion. The problem of fixing rod breakage is effectively avoided.
作者 马素娟 孙得维 闫焕敏 Ma Sujuan;Sun Dewei;Yan Huanmin(Tangshan Vocational College of Science and Technology,Tangshan 063000,China;Tangshan Shougang Jingtang Xishan Coking Co.,Ltd.,Tangshan 063200,China)
出处 《燃料与化工》 2018年第3期27-28,共2页 Fuel & Chemical Processes
关键词 集气系统 PROven系统 固定杯 固定杆 Gas collecting system PROven system Fixing cup Fixing rod