摘要 为了降低整流桥、变频器等强非线性负载向电网引入的谐波污染,提出一种由并联型有源电力滤波器(SAPF)与晶闸管投切滤波器(TSF)构成的T-SAPF混合滤波系统。针对TSF可能与电网发生并联谐振的问题,在对谐振机理进行分析的基础上,提出一种可以抑制系统并联谐振的SAPF虚阻尼控制策略,将自调谐滤波算法应用于阻尼电流指令的提取,并根据三个约束条件来界定阻尼系数的有效值域。仿真结果表明,该虚阻尼控制策略能够有效抑制系统的并联谐振,降低谐振时PCC电压的畸变程度,同时保证谐波电流的补偿效果。 In order to reduce the harmonic pollution in the grid caused by strong nonlinear loads such as rectifier and inverter,ahybrid filtering system TSAPF composed of shunt active power filter (SAPF)and thyristor switched filter (TSF)is proposedin this paper. In view of the parallel resonance potentially arised between TSF and the grid,the resonance mechanism isanalyzed in detail and a virtual damping control strategy of SAPF for suppressing parallel resonance of the system is proposed.The selftuned filtering algorithm is used to extract the instruction of damping current and the effective range of the dampingcoefficient is defined by three constraint conditions.The simulation results show that the parallel resonance of the system can beeffectively restrained by the proposed virtual damping control strategy,the distortion degree of the PCC voltage in the resonanceis reduced,and the effect of harmonic current compensation is also guaranteed.
作者 魏家昊 宋海洋 赵玉林 常鑫瑞 WEI Jiahao;SONG Haiyang;ZHAO Yulin;CHANG Xinrui(State Grid Taizhou Power Supply Company,Taizhou,225300,China;State Grid Jiangsu Electric Power Co.,Ltd. Research Institute,Nanjing,211103,China;School of Electrical Engineering & Automation,Harbin Istitute of Technology,Harbin,150001,China)
出处 《电力工程技术》 2018年第3期48-54,共7页 Electric Power Engineering Technology
基金 国家自然科学基金资助项目(51177028)
关键词 T-SAPF 虚阻尼控制 阻尼系数 谐振抑制 谐波补偿 TSAPF virtual damping control damping coefficient resonance suppression harmonic compensation
  • 相关文献

参考文献3

二级参考文献46

共引文献43

同被引文献32

引证文献2

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部