期刊文献+

基于252kV三相盆式绝缘子水压试验的仿真分析及结构优化 被引量:10

Simulation Analysis and Structure Optimization Based on the Hydrostatic Test of 252 kV Three-phase Basin-type Insulator
下载PDF
导出
摘要 文中描述了252 kV三相盆式绝缘子破坏水压试验的情况,为明确三相盆式绝缘子破坏水压不能满足标准要求的原因,首先对252 kV三相盆式绝缘子进行了建模、仿真与分析,明确了三相盆式绝缘子相间盆式结构交汇处应力集中是破坏水压偏低的原因。随后对模型进行了改进,将应力集中由‘Y’型分布转化为‘△’型分布,显著降低了最大应力值,显著改善了盆式绝缘子的耐压状态。最后讨论给出了252 kV三相盆式绝缘子在强度设计过程中应结合仿真计算进行机械强度设计的基本思想。文中的工作为三相盆式绝缘子的设计提供了一定的参考。 The destructive hydrostatic test of 252 kV three-phase basin-type insulator is described in this paper.Inorder to clarify why the destructive hydrostatic test of three-phase basin-type insulator could not meet the standardrequirements,investigations are carried out in this paper.Firstly,the three-phase basin-type insulator is modeled,simulated and analyzed.It is specified that the stress concentration at the intersection of three-phase basin-typeinsulators causes lower pressure during destructive hydrostatic test.Secondly,the structure of the insulator isoptimized and its ability of resisting compression is improved remarkably by changing the stress concentration from‘Y'type distribution to‘△'type distribution.Finally,some basic ideas for mechanical strength in optimizationdesign are proposed,which are that simulations should be taken into account during the mechanical strength designfor 252 kV three-phase basin-type insulator.Therefore,the work in this paper can provide useful references for thedesign of three-phase basin-type insulators.
作者 武胜斌 姜旭 辛昭昭 金松安 马占峰 陈志彬 WU Shengbin, JIANG Xu, XIN Zhaozhao, JIN Song' an, MA Zhanfeng, CHEN Zhibin(Xi'an XD Electric Research Institute Co., Ltd., Xi'an 710075, Chin)
出处 《高压电器》 CAS CSCD 北大核心 2018年第5期133-137,143,共6页 High Voltage Apparatus
关键词 有限元 机械强度 盆式绝缘子 finite element mechanical strength basin-type insulator
  • 相关文献

参考文献10

二级参考文献87

共引文献169

同被引文献97

引证文献10

二级引证文献39

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部