摘要 本文介绍了IEC 60335-1第5.2版较国内现行的等同采用的4.1版的主要差异,包括III类器具与III类结构、功能接地、输入功率和电流、最大正常温升、工作温度下的泄漏电流、电源软线绝缘等内容。 An introduction to IEC 60335-1:2010+A1:2013(Ed 5.1)+A2:2016(Ed 5.2) as compared to the previous edition(Ed 4.1) of the standard is mainly about its corrigendum and amendment, including class Ⅲ appliance and class Ⅲ structure, functional earthing, power input and current, maximum normal temperature rises, leakage current at operating temperature, insulation of the supply cords.
作者 蔡向明 汤培勇 潘海宁 CAI Xiangming;TANG Peiyong;PAN Haining(Shanghai Institute of Quality Inspection and Technical Research Shanghai 20023)
出处 《家电科技》 2018年第5期68-69,62,共3页 Journal of Appliance Science & Technology
关键词 IEC 60335-1 Ⅲ类器具与Ⅲ类结构 功能接地 温升 泄漏电流 绝缘 IEC 60335-1 Class Ⅲ appliance and class Ⅲ structure Functional earthing Temperature rises Leakage cnrrent Insulation