基于NHHT的谐振接地系统单相接地故障特征分析

Analysis of Single-phase Grounding Fault in Resonant Grounded System Based on NHHT
下载PDF
导出
摘要 归一化的希尔伯特-黄变换是一种改进的希尔伯特-黄变换,NHHT可以更好地从非平稳非线性的故障电流信号中提取丰富的时频信息。建立了谐振接地系统单相接地故障暂态等值模型,从理论上分析了系统暂态接地电流特征,使用EMTP-ATP仿真谐振接地系统单相接地故障。NHHT分析结果表明,该仿真故障接地电流特征频带为200 Hz至400 Hz,且在250 Hz处到达最大值。联合时-频幅值谱显示了故障信号的时频信息,希尔伯特边际谱则动态地反应了故障信号的幅频特性。研究表明,不同故障初相角对故障接地电流有较大影响。 Normalized Hilbert Huang Transform( NHHT) is an advanced Hilbert Huang Transform( HHT). NHHT can better extract rich time-frequency information from the non-stationary and nonlinear fault current signal. The characteristics of the equivalent model of the transient grounded current of a resonant grounded system are analyzed theoretically. The fault grounded current is simulated by EMTP-ATP. The result shows that the characteristic band of fault ground current is 200 Hz to 400 Hz,and the fault ground current reaches the maximum at 250 Hz. United time-frequency amplitude spectrum shows the time-frequency information of the fault signal while Hilbert marginal spectrum can better reflect the amplitude-frequency characteristics of the fault signal. Studies have shown that the different initial phase angle has great effects on fault ground current.
作者 刘宏超 武源明 何晓宇 刘景 张林 肖本贤 LIU Hong-chao1,WU Yuan-ming1,HE Xiao-yu1,LIU Jing1,ZHANG Lin2,XIAO Ben-xian2(1. State Grid Xianyang Xingping Power Company, Xianyang 713100, China; 2. School of Electrical Engineering and Automation, Hefei University of Technology, Hefei 230009, Chin)
出处 《仪表技术》 2018年第5期1-5,14,共6页 Instrumentation Technology
基金 国家电网公司科技项目资助(SGSNXY00YJJS1700402)
关键词 本征模态函数 经验模式分解 联合时-频幅值谱 希尔伯特边际谱 暂态接地电流 IMF EMD united time-frequency spectrum Hilbert marginal spectrum (HMS) transient grounded current
  • 相关文献

参考文献3

二级参考文献26

  • 1王耀南,霍百林,王辉,何晓.基于小波包的小电流接地系统故障选线的新判据[J].中国电机工程学报,2004,24(6):54-58. 被引量:162
  • 2赵慧梅,张保会,段建东,周德才,张文豪.一种自适应捕捉特征频带的配电网单相接地故障选线新方案[J].中国电机工程学报,2006,26(2):41-46. 被引量:45
  • 3束洪春,刘娟,王超,司大军,张杰.谐振接地电网故障暂态能量自适应选线新方法[J].电力系统自动化,2006,30(11):72-76. 被引量:46
  • 4苗友忠 孙雅明 杨华(Miao Youzhong Sun Yaming Yang Hua).配电网馈线单相接地故障中性点不接地模式暂态电流保护的新原理(A newprinciple of transient current grounded relay for feeder in distribution systems-ungrounded-neural mode)[J]..
  • 5曾祥君 尹项根 于永源 等(Zeng Xiangjun Yin Xianggen Zhang Zhe et al).基于注入变频信号法的经消弧线圈接地系统控制与保护新方法[J]..
  • 6ZAMORA I,MAZON A J,EGUIA P.Influence of resonantcoil tuning in the fault current[C]//Proceedings of the 12thIEEE Mediterranean Electrotechnical Conference:Vol 3,May12-15,2004,Dubrovnik,Croatia:979-982.
  • 7DONG Xinzhou,SHI Shenxing.Identifying single-phase-to-ground fault feeder in neutral noneffectively groundeddistribution system using wavelet transform[J].IEEE Trans onPower Delivery,2008,23(4):1829-1837.
  • 8Qin S, Chen DP. Joint Time-Frequency Analysis[J]. IEEE Signal Processing Magazine, 1999, 16(2): 52-67.
  • 9boashash B. Estimating and Interpreting the Instantaneous Frequency of a Signal--Part 1:Fundamentals[J]. Proc. IEEE, 1992, 80(4): 520-538.
  • 10Champency C D. A Handbook of Fourier Theorems[M]. London: Cambridge University Press, 1987.