期刊文献+

基于高精细度光腔锁频激光的分子吸收光谱测量 被引量:8

Measurement of molecular absorption spectrum with a laser locked on a high-finesse cavity
下载PDF
导出
摘要 利用高精细度光腔锁定激光频率,实现了对分子吸收光谱的高精度测量.光腔采用低热膨胀系数的殷钢结构设计和温度控制,实现了腔长度的稳定;通过将激光频率锁定在光腔纵模上,实现了高频率精度和高灵敏度的光腔衰荡光谱测量.利用该装置示范性地测量了二氧化碳分子在6470.42 cm^(-1)附近的光腔衰荡光谱和色散光谱,得到了高精度的谱线参数,并和数据库谱线参数进行了对比. High-resolution and high-sensitivity molecular spectroscopy is widely used in fundamental molecular physics,atmospheric studies, remote sensing, industrial process monitoring, and medical diagnostics. Accurate determination of the parameters of molecule absorption lines, such as line positions, line strengths, line widths and profiles, is essential to support these studies and applications. For example, in order to retrieve the column density of carbon dioxide with a precision of one part per million(ppm), we need laboratory data of line positions with a uncertainty lower than 0.3 MHz and line intensities with a relative accuracy better than 0.5%.Here we present precision spectroscopy of molecules using a laser locked with a high-finesse cavity. The cavity made of invar is thermo-stabilized to reduce the drifts of its length and the cavity mode frequencies. The frequency of the probe laser is locked on a longitudinal mode of the cavity by using the Pound-Drever-Hall method. Another beam from the probe laser, which is frequency shifted and on resonance with a nearby longitudinal mode of the cavity, is used for cavity ring-down spectrum(CRDS) measurement. The CRDS absorption spectrum is recorded by stepping the modulation frequency of a fiber electro-optic modulator in increment of the mode spacing of the cavity. Note that the cavity mode frequencies are shifted due to the dispersion introduced by the absorption lines. Prior to the CRDS measurements, the transmittance spectra of the cavity modes are recorded by scanning the probe laser frequencies over the resonance, which allows the determination of the cavity mode frequencies with an accuracy at a Hz level. Therefore,a dispersion spectrum is also obtained using the same setup by measuring the frequency shifts of cavity modes of the samples with and without absorption. The absolute frequency of the probe laser is determined by an optical frequency comb referring to a GPS-disciplined rubidium clock. The long term drift of beat frequency between the optical frequency comb and the probe laser is measured to be about 1.8 MHz per hour, which is consistent with the thermal expansion of the cavity under a temperature drift of 50 mK.The performance of the spectrometer is demonstrated by measuring the Doppler-broadened spectra of CO2 around6470.42 cm^-1. Precise spectroscopic parameters are derived from both the absorption and dispersion spectra recorded by the same spectrometer. The line position is determined with an accuracy of 0.18 MHz, which is over one order of magnitude better than those given in previous studies and spectral databases.
作者 康鹏 孙羽 王进 刘安雯 胡水明 Kang Peng ,Sun Yu ,Wang Jin ,Liu An-Wen, Hu Shui-Ming(Hefei National Laboratory for Physical Sciences at the Microscale, University of Science and Technology of China, Hefei 230026, Chin)
出处 《物理学报》 SCIE EI CAS CSCD 北大核心 2018年第10期73-79,共7页 Acta Physica Sinica
基金 国家自然科学基金(批准号:21688102 21427804)资助的课题~~
关键词 激光锁频 光腔衰荡光谱 色散光谱 分子吸收 laser locked cavity ring-down spectroscopy dispersion spectroscopy molecular absorption
  • 相关文献

同被引文献66

引证文献8

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部