摘要
针对核电站大直径厚壁环焊缝射线检测灵敏度下降的问题,以核电站主管道为试验对象,对缺陷自身高度、缺陷宽度、射线源焦点尺寸、缺陷深度、射线源角度和射线源位置等主要影响因素进行重点分析,通过CIVA软件的模拟,以及带缺陷试块的透照试验,得出了影响射线检测灵敏度的几个重要因素。
Due to the sensitivity of the X-ray inspection decreased in thick-walled workpiece inspection,the main pipeline of nuclear power plant was used as the research object,and the major influencing factors of the height and width of the defect,the X-ray focus size,defect depth,and the angle and position of X-ray source were analyzed.Through the software CIVA simulation and radiography of test block,several important factors affecting the sensitivity of radiographic inspection were shown.
作者
梅义俊
王琪
温庆全
银帮耀
苏海敏
华雄飞
MEI Yijun;WANG Qi;WEN Qingquan;YIN Bangyao;SU Haimin;HUA Xiongfei(CGN Inspection Technology Co., Ltd., Suzhou 215021, China;Guangxi Fangchenggang Nuclear Power Co.,Ltd., Fangchenggang 538003, China)
出处
《无损检测》
2018年第5期36-41,共6页
Nondestructive Testing
关键词
核电站
射线检测
灵敏度
大直径厚壁工件
nuclear power plant
radiographic examination
sensitivity
large diameter thick-walled workpiece