期刊文献+

平板对接焊缝射线检测中管电压对散射比的影响

Tube Voltage Effect on Scattering Ratio in Radiographic Testing for Plate Butt Welds
下载PDF
导出
摘要 为了了解平板对接焊缝射线检测中管电压对散射比的影响,并更好地保证底片影像质量,在其他透照参数不变的情况下,通过改变管电压来研究散射比的变化规律。结果表明:在管电流、曝光时间和焦距等参数相同的条件下,随着管电压的增加,散射比呈减小的趋势。试验为平板对接焊缝射线检测中管电压的选取提供了参考依据。 In order to analyze the voltage effect on scattering ratio in radiographic testing for plate butt welds,so as to better guarantee the image quality of film,in this paper,the variation of scattering ratio is experimented by changing the voltage under the condition of other parameters being invariant.The results show that the scattering ratio decreases with the increase of the tube voltage when the parameters such as tube current,exposure time and focal length are fixed.The experiment provides a reference for the selection of tube voltage in the radiographic testing for plate butt welds.
作者 于德军 廖良进 曾令青 张学锋 刘贵吉 YU Dejun;LIAO Liangjin;ZENG Lingqing;ZHANG Xuefeng;LIU Guiji(Offshore Oil Engineering Co., Ltd., Qingdao 266520, Chin)
出处 《无损检测》 2018年第5期56-57,63,共3页 Nondestructive Testing
关键词 射线检测 平板对接焊缝 散射比 管电压 radiographic testing plate butt weld scattering ratio tube voltage
  • 相关文献

参考文献3

二级参考文献18

  • 1杨晓华,危昭才.TG—1型胶片特性曲线曝光仪和特性曲线的制作方法[J].无损探伤,1994(4):40-41. 被引量:1
  • 2杨学恒,苏显素,赵炬.γ射线在ICT中的能谱硬化与散射修正[J].CT理论与应用研究(中英文),1995,4(3):25-39. 被引量:6
  • 3日本非破坏检查协会.射线探伤B[M].无损探伤编辑部,1988..
  • 4Cao Z-J, Fery E C, Tsui B M W. A scatter model parallel and converging beam SPECT based on the Klein- Nishina formula[J]. IEEE Transaction on Nuclear Science, 1994,41(4) : 1594-1599.
  • 5Leiliveld C J, Maas J G, Van Eijk C W E, et al. On the significance of scattered radiation in ndustrial X-ray computerized tomographic imaging[J]. IEEE Transaction on Nuclear Science, 1994,41(1):290-294.
  • 6Hanke R, Bobel F. Determination of material flaw size by intensity evaluation of polychromatic X-ray transmission[J].NDT&E International, 1992,25 (2) : 87.
  • 7Guy M J, Castellano-Smith I A, Flower M A, et al.Detect-dual engergy transmission estimation CT for improved attenuation correction in SPECT and PET [J]. IEEE Transaction on Nuclear Science, 1998, 45 (3) : 1261-1265.
  • 8Rogerio Ferreira de Paiva, John Lynch, Elisabeth Rosenberg, et al. A beam hardening correction for X-ray microtomography[J]. NDT & International, 1998, 31(1):17-22.
  • 9Liao Changgeng, Yuan Junqian, He Haiyan, et al. Studied on theory and application of nondestructive inspection using eompton scattering[J]. Kexue Tongbao, 1987,32(8): 517.
  • 10Lopes R T, Valente C M, De Jesus E F O, et al. Detection of paraffin deposition inside a draining tubulation by the compton scattering technique[J]. Appl Radiat Isot, 1997,48(10-12) : 1443-1450.