应用PDCA降低检验科危急值漏报率 被引量:12

Reduce the Under-Reporting Rate of Critical Value in Clinical Laboratory by Using PDCA
下载PDF
导出
摘要 以医院三甲复评为契机,引入PDCA循环,对检验科危急值漏报率高的问题进行改进。针对危急值项目设置过多,网络报告系统不完善,门诊危急值管理缺陷,主管部门监管力度不足,不熟悉报告处理流程等原因,从调整危急值项目及范围,开发网络直报软件,完善门诊危急值报告制度及流程,加大监管力度,加强员工培训等方面改进。通过改进,检验科危急值平均每月漏报率从1.04%下降为0,实现了危急值100%上报;检验科危急值平均确认时间从17.9分钟缩短到6.2分钟,为危重患者临床抢救争取了更多时间。 With the opportunity of the tertiary hospital review, the PDCA cycle was introduced to improve the problem of the high under-reporting rate of critical value in clinical laboratory. The causes included setting up too many critical value items, incomplete network reporting system, critical value management flaws in outpatients department, inadequate supervision by competent authorities, unfamiliarity with the report processing flow, etc. Improvement was made from aspects of adjusting critical value items and scope, developing online reporting software, and improving outpatient critical value reporting system and processes, intensifying supervision, and strengthening employee training. Through improving, the average monthly under-report rate of critical value in clinical laboratory dropped from 1.04% to 0, achieving 100% report of critical value. The average confirmation time of critical value was shortened from 17.9 minutes to 6.2 minutes, which strived for more time for clinical rescue of critically ill patients.
作者 伍启康 李炜煊 赵伟成 黄慧勇 曾勇 潘练华 WU Qikang;LI Weixuan;ZHAO Weicheng(The First People's Hospital of Foshan, Foshan,Guangdong, 528000, Chin)
出处 《中国卫生质量管理》 2018年第3期15-17,共3页 Chinese Health Quality Management
关键词 PDCA循环 检验科 危急值 漏报 PDCA Cycle Clinical Laboratory Critical Value Under-Reporting
  • 相关文献

参考文献10

二级参考文献44

  • 1李贵芳,王树辉,周湘红.临床检验危急值的建立与应用[J].检验医学与临床,2006,3(8):380-381. 被引量:38
  • 2张真路,刘泽金,赵耿生,杨军,王文武,崔敏.临床实验室危急值的建立与应用[J].中华检验医学杂志,2005,28(4):452-453. 被引量:149
  • 3葛荣跃,张伟民.设置检验科危急值和报告制度的重要性[J].江西医学检验,2007,25(1):55-56. 被引量:37
  • 4寇丽筠.临床实验室工作中危急值的应用.实验室与临床,2003,6(2):32-34.
  • 5樊有龙,王小中,吕娇风,张玲玲.临床实验室危急值的建立及应用体会[J].江西医学检验,2007,25(4):366-366. 被引量:16
  • 6各省质检信息化的发展状况及其主要特点[DB/OL].http://xxhs.miit.gov.
  • 7卫生部医管司指导,中国医院协会编写.三级综合医院评审标准[M].北京:人民卫生出版社,2011:66-67.
  • 8ISO. ISO 15189 Medical laboratories particular requirements for quality and competence[S. Geneva, Switzerland : IS() Central Sec retariat, 2012.
  • 9Lundberg GD. When to panic over abnormal values[J].MedLab Observer, 1972,4:47-54.
  • 10Howanitz PJ, Steindel SJ, Heard NV. Laboratory critical values policies and procedures:a college of American Pa- thologists Q-probes study in 623 institutions [J]. Arch Pathol Lab Med,2002,126(6) :663-669.

共引文献96

同被引文献107

引证文献12

二级引证文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部