文章根据大量的日常检定经验,梳理总结了在检定移液器过程中常见的技术问题,并给出了解决方案。同时,针对检定不合格移液器,提供了一些简单易行的调修方法。从而提高检定人员的检定质量和技术能力,提升对客户的服务水平。
According to a large number of daily verification experiences, the thesis summarizes the common technical problems in the verification of pipettes and gives solutions. At the same time, for the verification of unqualified pipettes, some simple and easy methods of adjust and repair are provided. In this way, the quality and technical ability of the verification personnel can be improved, thus the service level to the customer can be also improved.
出处
《计量与测试技术》
2018年第5期60-61,共2页
Metrology & Measurement Technique
关键词
移液器
检定
不合格
调修
pipette
verification
failure
adjust and repair