摘要
针对石化行业的超滤/反渗透(reverse osmosis,RO)浓水处理问题,选取天津某港石化公司RO膜生产车间产生的RO浓水,采用臭氧-光降解-碳纤维处理技术,进行中试试验。结果表明:最佳pH值为8~9,臭氧最佳投加质量浓度为10.0~13.3 mg/L;系统最终出水COD的质量浓度小于40 mg/L,累计NH3-N去除率最高为44.6%,SS达到一级排放标准;处理RO浓水的成本为2.1元/t;增加内回流比,可以提高NH3-N去除率;碳纤维装置进水pH值为8时,吸附效率最高。
Aiming at the treatment of petrochemical RO concentrated water,the technique of O3-photodegradationcarbon fiber was used to treat the wastewater from a petrochemical corporation in Tianjin and a pilot-scale experiment was carried out. The results show that the optimum pH value is 8 - 9 and the optimum concentration of O3 is 10. 0 - 13. 3 mg/L. COD concentration of the final effluent is less than 40 mg/L,the maximum NH3-N removal rate is 44. 6%,and the SS reaches the first grade discharge standard. The operating cost of RO concentrated water is 2. 1 CNY per ton. The removal rate of NH3-N can be increased by increasing the internal reflux ratio. When the pH value of the intake water of the carbon fiber device is 8,the adsorption efficiency is the highest.
作者
罗德芳
陈纪赛
葛成城
周永贤
LUO Defang;CHEN Jisai;GE Chengcheng;ZHOU Yongxian(Design Institute of Nanjing Luzhou Environment Protection Limited Company, China State Shipbuilding Corporation, Nanjing 210039, China)
出处
《水资源保护》
CAS
CSCD
北大核心
2018年第3期80-84,共5页
Water Resources Protection
关键词
石化RO浓水
臭氧
光降解
碳纤维
petrochemical RO concentrated water
O3
photodegradation
carbon fiber