期刊文献+

不同波长近红外人体血管成像技术研究 被引量:2

Research on different wavelengths near infrared imaging of human blood vessels
下载PDF
导出
摘要 针对通过研制的血管成像装置采集到的图像不可避免地会受到本身或外界因素的噪声污染,肉眼很难分辨出图像质量的问题,提出了对在不同波长近红外光下采集的人体血管图像进行CLAHE增强和Ni Black算法处理,并通过多组实验对比处理前后图像的质量。实验结果表明:在近红外光反射照射下,940 nm单色光采集的手臂血管成像效果最佳,760 nm和940 nm混合光次之,760 nm单色光采集效果不理想。 Aiming at problem that images collected by the vascular imaging device will inevitably be polluted by themselves or external factors, so it is difficult for the naked eye to distinguish quality of image, propose CLAHE enhancement and NiBlack algorithm processing are carried out on human blood vessel images collected in near infrared light of different wavelengths, and image quality is compared before and after treatment by multiple groups of experiments. The experimental resuhs show that in reflection of near-infrared light, effect of arm blood vessels imageing collect by 93.0 nm monochromatic light has the best quality ,760 nm and 940 nm mixed light compared is the second,effect collected by 760 nm monochromatic light is not ideal.
作者 杨小庆 王年 杨云雷 YANG Xiao-qing;WANG Nian;YANG Yun-lei(School of Electronics and Information Engineering, Anhui University, Hefei 230601, China)
出处 《传感器与微系统》 CSCD 2018年第5期58-60,共3页 Transducer and Microsystem Technologies
关键词 血管成像 CLAHE增强 NiBlack算法 混合光 angiography CLAHE enhancement NiBlack algorithm mixed light
  • 相关文献

参考文献1

二级参考文献7

  • 1N Venkata Vara Prasad , K Venkata Muralx Mohan. A realtime embedded finger vein recognition system for authenti -cation on mobile devices[J].International Journal of Engi-neering Trends and Technology , 2014(2) : 105-108.
  • 2C Praveen , G Magdalin joenita , S Yamuna devi.Enhancedsecurity system using an embedded real-time finger-veindetection [ J ]. International Journal of Applied EngineeringResearch,2015(8) : 21501-21507.
  • 3Goh Kah Ong Michael,Tee Connie , Andrew Beng Jin Teoh.A contactless biometric system using multiple hand featuresfj].Journal of Visual Communication and Image Representation2012(7);1068-1084.
  • 4Stefan Langemeyer, Peter Pirsch , Holger Blume.UsingSDRAM memories for high - performance accesses to two-dimensional matrices without transpose [ J ]. InternationalJournal of Parallel Programming , 2013(2) : 331-354.
  • 5杨数强,余成波,崔焱喆,李彦林.手指静脉智能采集装置的研制[J].计算机工程与设计,2009,30(21):4977-4979. 被引量:5
  • 6管凤旭,姜智超,吴秋雨,王科俊,孟祥宇.指静脉与折痕双模态图像采集系统设计[J].传感器与微系统,2013,32(2):124-127. 被引量:10
  • 7高战立,余桂英,唐玮.FPGA图像采集系统研究与设计[J].中国计量学院学报,2014,25(1):75-79. 被引量:7

共引文献4

同被引文献17

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部