摘要
对管式GGH和回转式GGH做了比较,介绍了管式GGH烟气冷却器传统模块结构型式,论述了管式GGH烟气冷却器受热面模块U型弯头一端改为胀接管板的方案,并且将这两种方法在工程中的运用做了成本比较,最终得出一端采用胀接管板成本低的结论。
This article compare tube type GGH and rotary GGH.Introducted troductional frame of tube type GGH.And tell about the heating surface module expansion joint plate of flue gas cooler instead of U elbow in GGH.And compareing the two method cost in engineering application.Finally,the conclusion is drawn that the cost of the expansion joint is low.
作者
卢友艳
LU Youyan(Shanghai Clyde Bergemann Machinery Co. , Ltd. , Shanghai 200082, Chin)
出处
《锅炉技术》
北大核心
2018年第3期44-46,共3页
Boiler Technology